【 摘 要 】

BACKGROUND: Chronic lung allograft dysfunction (CLAD), including the phenotypes of bronchiolitis obliterans syndrome (BOS) and restrictive CLAD (R-CLAD), represents the leading cause of late death after lung transplantation. Little is known, however, regarding the natural history or prognostic significance of pulmonary function changes after the onset of these conditions. We examined changes in forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) over the first 18 months after CLAD. We also sought to determine whether lung function changes occurring early after CLAD impact longer term outcomes. METHODS: We performed a retrospective analysis of 216 bilateral lung recipients with CLAD, which included those with R-CLAD (n = 65) or BOS (n = 151). The course of FEV1 and FVC after CLAD was described. Cox proportional hazards models were used to evaluate the impact of a >= 10% decline in FEV1 or FVC within the first 6 months of CLAD on graft loss after that time. RESULTS: Lung recipients with CLAD, whether BOS or R-CLAD, had the largest decreases in FEV1 and FVC within the first 6 months after onset. Moreover, a decline in FEV1 or FVC of = 10% within the first 6 months after CLAD was associated with a significantly increased hazard for graft loss after that time (hazard ratio [HR] = 3.17, 95% confidence interval [CI] 1.56 to 6.42, p = 0.001, and HR = 2.80, 95% CI 1.66 to 4.70, p <= 0.001, respectively), an effect observed in both BOS and R-CLAD patients. CONCLUSIONS: Early physiologic changes after CLAD were independently associated with graft loss. This suggests lung function changes after CLAD, specifically a >= 10% decline in FEV1 or FVC, could be a surrogate measure of graft survival. (C) 2018 International Society for Heart and Lung Transplantation. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_healun_2018_10_006.pdf 1310KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次