Spatial distribution of Legionella pneumophila MLVA-genotypes in a drinking water system
Article
Rodriguez-Martinez, Sarah1  Sharaby, Yehonatan1  Pecellin, Marina2  Brettar, Ingrid2  Hoefle, Manfred2  Halpern, Malka1,3 
[1] Univ Haifa, Fac Nat Sci, Dept Evolutionary & Environm Biol, IL-31999 Haifa, Israel
[2] Helmholtz Ctr Infect Res HZI, Dept Vaccinol & Appl Microbiol, Braunschweig, Germany
[3] Univ Haifa, Fac Nat Sci, Dept Biol & Environm, Oranim, Tivon, Israel
关键词: Legionella;    Drinking water;    Biofilm;    MLVA genotyping;    Bacteria monitoring;   
DOI  :  10.1016/j.watres.2015.03.010
来源: Elsevier
PDF
【 摘 要 】

Bacteria of the genus Legionella cause water-based infections, resulting in severe pneumonia. To improve our knowledge about Legionella spp. ecology, its prevalence and its relationships with environmental factors were studied. Seasonal samples were taken from both water and biofilm at seven sampling points of a small drinking water distribution system in Israel. Representative isolates were obtained from each sample and identified to the species level. Legionella pneumophila was further determined to the serotype and genotype level. High resolution genotyping of L. pneumophila isolates was achieved by Multiple-Locus Variable number of tandem repeat Analysis (MLVA). Within the studied water system, Legionella plate counts were higher in summer and highly variable even between adjacent sampling points. Legionella was present in six out of the seven selected sampling points, with counts ranging from 1.0 x 10(1) to 5.8 x 10(3) cfu/l. Water counts were significantly higher in points where Legionella was present in biofilms. The main fraction of the isolated Legionella was L. pneumophila serogroup 1. Serogroup 3 and Legionella sainthelensis were also isolated. Legionella counts were positively correlated with heterotrophic plate counts at 37 degrees C and negatively correlated with chlorine. Five MLVA-genotypes of L. pneumophila were identified at different buildings of the sampled area. The presence of a specific genotype, MLVA-genotype 4, consistently co-occurred with high Legionella counts and seemed to trigger high Legionella counts in cold water. Our hypothesis is that both the presence of L. pneumophila in biofilm and the presence of specific genotypes, may indicate and/or even lead to high Legionella concentration in water. This observation deserves further studies in a broad range of drinking water systems to assess its potential for general use in drinking water monitoring and management. (c) 2015 Elsevier Ltd. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_watres_2015_03_010.pdf 1373KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:0次