| WATER RESEARCH | 卷:126 |
| Comparative power demand of mechanical and aeration imposed shear in an immersed membrane bioreactor | |
| Article | |
| Buzatu, P.1  Qiblawey, H.2  Nasser, M. S.1  Judd, S.1,3  | |
| [1] Qatar Univ, Gas Proc Ctr, Doha, Qatar | |
| [2] Qatar Univ, Dept Chem Engn, Doha, Qatar | |
| [3] Cranfield Univ, Cranfield Water Sci Inst, Cranfield, Beds, England | |
| 关键词: Membrane bioreactor; Mechanical shear; Membrane aeration; Sludge rheology; Power; Flat sheet; | |
| DOI : 10.1016/j.watres.2017.09.024 | |
| 来源: Elsevier | |
PDF
|
|
【 摘 要 】
The power demanded for the application of mechanically-imposed shear on an immersed flat sheet (iFS) membrane bioreactor (MBR) has been compared to that of conventional membrane air scouring. Literature correlations based on the Ostwald model were used to define the rheological characteristics of an MBR sludge. The correlation of specific power demand ((P) over bar', in Watts per m(2) membrane area) with shear rate,gamma in s(-1) was developed from first principles through a consideration of the force balance on the system in the case of mechanically-imposed shear. The corresponding aeration imposed shear correlation was interpreted from literature information. The analysis revealed the energy required to impose a shear mechanically through oscillation (or reciprocation) of the membrane to be between 20 and 70% less than that demanded for providing the same shear by conventional aeration of the immersed membrane. The energy saving increases with decreasing shear in accordance with a power demand ratio (aeration:mechanical) of 1400 gamma(-1.4) for a specific sludge rheology. Whilst the absolute (P) over bar' value is dependent on the sludge rheology, the aeration:mechanical power demand ratio is determined by the difference in the two exponents in the respective correlations between (P) over bar' and,gamma. Consequently, aeration-imparted shear becomes energetically favoured beyond some threshold shear rate value (similar to 180 s(-1), based on the boundary conditions applied in the current study). The outcomes qualitatively corroborate findings from the limited practical measurement of energy demand in MBRs fitted with reciprocating immersed membranes. (C) 2017 Elsevier Ltd. All rights reserved.
【 授权许可】
Free
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 10_1016_j_watres_2017_09_024.pdf | 4808KB |
PDF