Background: The assessment of hemodynamics in patients supported with left ventricular assist devices (LVADs) is often challenging. Physical examination maneuvers correlate poorly with true hemodynamics. We assessed the value of novel transthoracic echocardiography (TTE)-derived variables to reliably predict hemodynamics in patients supported with LVAD. Methods and Results: A total of 102 Doppler-FIE images of the LVAD outflow cannula were obtained during simultaneous invasive right heart catheterization (RHC) in 30 patients supported with continuous-flow LVADs (22 HMII, 8 HVAD) either during routine RHC or during invasive ramp testing. Properties of the Doppler signal though the outflow cannula were measured at each ramp stage (RS), including the systolic slope (SS), diastolic slope (DS), and velocity time integral (VTI). Hemodynamic variables were concurrently recorded, including Doppler opening pressure (MAP), heart rate (HR), right atrial pressure, pulmonary artery pressure, pulmonary capillary wedge pressure (PCWP), Fick cardiac output (CO) and systemic vascular resistance (SVR). Univariate and multivariate regression analyses were used to explore the dependence of PCWP, CO, and SVR on DS, SS, VTI, MAP, HR, and RS. Multivariate linear regression analysis revealed significant contributions of DS on PCWP (PCWPpred = 0.164DS + 4.959; R = 0.68). Receiver operating characteristic (ROC) curve analysis revealed that PCWPpred could predict an elevated PCWP >= 18 mm Hg with a sensitivity (Sn) of 94% and specificity (Sp) of 85% (area under the ROC curve 0.88). CO could be predicted by RS, VTI, and HR (COpred = 0.017VTI + 0.016HR + 0.12RS + 2.042; R = 0.61). COpred could predict CO <= 4.5 L/min with Sn 73% and Sp 79% (AUC 0.81). SVR could be predicted by MAP, VTI, and HR (SVRpred = 15.44MAP - 5.453 VTI - 6.349HR + 856.15; R = 0.84) with Sn 84% and Sp 79% (AUC 0.91) to predict SVR >= 1200 dyn-s/cm(5). Conclusions: Doppler-TTE variables derived from the LVAD outflow cannula can reliably predict PCWP, CO, and SVR in patients supported with LVADs and may mitigate the need for invasive testing.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_cardfail_2018_07_004.pdf 1377KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:0次