期刊论文详细信息
Frontiers in Endocrinology
Biomechanical analysis of sandwich vertebrae in osteoporotic patients: finite element analysis
Endocrinology
Cheng Xue1  Xianye Tang1  Xu Zhang2  Shaolong Huang2  Zhongjian Tang2  Chengqiang Zhou2  Xiao Meng2  Liangyu Liu3 
[1] Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China;Department of Orthopedics, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China;Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China;North Sichuan Medical College, Nanchong, Sichuan, China;
关键词: sandwich vertebra;    osteoporotic vertebral compression fracture;    percutaneous vertebroplasty;    adjacent vertebral fracture;    finite element analysis;   
DOI  :  10.3389/fendo.2023.1259095
 received in 2023-07-15, accepted in 2023-09-21,  发布年份 2023
来源: Frontiers
PDF
【 摘 要 】

ObjectiveThe aim of this study was to investigate the biomechanical stress of sandwich vertebrae (SVs) and common adjacent vertebrae in different degrees of spinal mobility in daily life.Materials and methodsA finite element model of the spinal segment of T10-L2 was developed and validated. Simultaneously, T11 and L1 fractures were simulated, and a 6-ml bone cement was constructed in their center. Under the condition of applying a 500-N axial load to the upper surface of T10 and immobilizing the lower surface of L2, moments were applied to the upper surface of T10, T11, T12, L1, and L2 and divided into five groups: M-T10, M-T11, M-T12, M-L1, and M-L2. The maximum von Mises stress of T10, T12, and L2 in different groups was calculated and analyzed.ResultsThe maximum von Mises stress of T10 in the M-T10 group was 30.68 MPa, 36.13 MPa, 34.27 MPa, 33.43 MPa, 26.86 MPa, and 27.70 MPa greater than the maximum stress value of T10 in the other groups in six directions of load flexion, extension, left and right lateral bending, and left and right rotation, respectively. The T12 stress value in the M-T12 group was 29.62 MPa, 32.63 MPa, 30.03 MPa, 31.25 MPa, 26.38 MPa, and 26.25 MPa greater than the T12 stress value in the other groups in six directions. The maximum stress of L2 in M-T12 in the M-L2 group was 25.48 MPa, 36.38 MPa, 31.99 MPa, 31.07 MPa, 30.36 MPa, and 32.07 MPa, which was greater than the stress value of L2 in the other groups. When the load is on which vertebral body, it is subjected to the greatest stress.ConclusionWe found that SVs did not always experience the highest stress. The most stressed vertebrae vary with the degree of curvature of the spine. Patients should be encouraged to avoid the same spinal curvature posture for a long time in life and work or to wear a spinal brace for protection after surgery, which can avoid long-term overload on a specific spine and disrupt its blood supply, resulting in more severe loss of spinal quality and increasing the possibility of fractures.

【 授权许可】

Unknown   
Copyright © 2023 Huang, Zhou, Zhang, Tang, Liu, Meng, Xue and Tang

【 预 览 】
附件列表
Files Size Format View
RO202311144750095ZK.pdf 9452KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:0次