Experimental study on helical tubes heat transfer characteristics considering corrosion products
Energy Research
Hu Yisong1  Mao Yulong1  Wang Xiaoting1  Hu Yousen1  Rui Min1  Lu Xianghui1  Jin Desheng1  Li Kejia1  Meng Shuqi2 
[1] China Guangdong Nuclear Research Institute Co., Ltd., Shenzhen, China;null;
关键词: H-OTSG;    helical tube;    heat transfer;    thermal resistance;    corrosion products;   
DOI  :  10.3389/fenrg.2023.1289831
 received in 2023-09-06, accepted in 2023-09-29,  发布年份 2023
来源: Frontiers
PDF
【 摘 要 】

During the power operation of nuclear reactors, the corrosion products in the secondary circuit will deposit on the inside of Helical-coiled One-Through Steam Generator (H-OTSG) heat transfer tubes and form fouling. The main component of fouling is iron-based oxide, which generates from the heat exchangers made of cast iron. Fouling may change the local heat transfer characteristics of heat transfer tubes, and then affect the safety and economy of reactors. In order to obtain the distribution of fouling thickness and its action mechanism on helical tubes heat transfer characteristics, the heat transfer experiment under small pressurized reactors service environment was conducted. The experimental results indicate: corrosion products mainly deposit on onset of saturated boiling point with the maximum fouling thickness of 50 μm, and induce local wall temperature elevating about 773 K; fouling will increase the thermal equilibrium void fraction and hinder the heat transfer of helical tube, but has little impact on the onset position of saturated boiling point; corrosion products will release and re-deposit near dry-out point because of the flush of high speed vapor, causing the periodic fluctuation of thermal resistance of helical tube.

【 授权许可】

Unknown   
Copyright © 2023 Yulong, Shuqi, Xianghui, Desheng, Xiaoting, Kejia, Yisong, Yousen and Min.

【 预 览 】
附件列表
Files Size Format View
RO202311143910307ZK.pdf 2643KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:0次