BMC Gastroenterology | |
‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’ | |
Research Article | |
William L. White1  Peter D. Mooney1  Michelle Shui Yee Lau1  David S. Sanders1  Simon S. Cross2  Gareth D. Corbett3  Joshua E. Elias3  Kiran Bundhoo3  Sulleman Moreea4  Victoria Appleby4  Liam Wong5  Her Hsin Tsai5  John M. Hebden6  Ismail Haythem7  Sami Hoque7  | |
[1] Academic Department of Gastroenterology, Royal Hallamshire Hospital, Sheffield Teaching Hospitals, Sheffield, UK;Academic Unit of Pathology, Department of Neuroscience, Faculty of Medicine, Dentistry & Health, The University of Sheffield, Sheffield, UK;Department of Gastroenterology, Addenbrooke’s Hospital, Cambridge, UK;Department of Gastroenterology, Bradford Royal Infirmary, Bradford, UK;Department of Gastroenterology, Hull Royal Infirmary, Hull, UK;Department of Gastroenterology, Northern General Hospital, Sheffield Teaching Hospitals, Sheffield, UK;Department of Gastroenterology, Whipps Cross University Hospital, London, UK; | |
关键词: Coeliac disease; Small intestine; Endoscopy; Histopathology; Iron deficiency anaemia; Diagnostic tests; Health economics; Screening; | |
DOI : 10.1186/s12876-016-0521-5 | |
received in 2016-04-19, accepted in 2016-08-16, 发布年份 2016 | |
来源: Springer | |
【 摘 要 】
BackgroundInternational guidelines recommend coeliac serology in iron deficiency anaemia, and duodenal biopsy for those tested positive to detect coeliac disease. However, pre-endoscopy serology is often unavailable, thus committing endoscopists to take routine duodenal biopsies. Some endoscopists consider duodenal biopsy mandatory in anaemia to exclude other pathologies. We hypothesise that using a point of care test at endoscopy could fill this gap, by providing rapid results to target anaemic patients who require biopsies, and save costs by biopsy avoidance. We therefore assessed three key aspects to this hypothesis: 1) the availability of pre-endoscopy serology in anaemia; 2) the sensitivities and cost effectiveness of pre-endoscopy coeliac screening with Simtomax in anaemia; 3) whether other anaemia-related pathologies could be missed by this targeted-biopsy approach.MethodsGroup 1: pre-endoscopy serology availability was retrospectively analysed in a multicentre cohort of 934 anaemic patients at 4 UK hospitals. Group 2: the sensitivities of Simtomax, endomysial and tissue-transglutaminase antibodies were compared in 133 prospectively recruited patients with iron deficiency anaemia attending for a gastroscopy. The sensitivities were measured against duodenal histology as the reference standard in all patients. The cost effectiveness of Simtomax was calculated based on the number of biopsies that could have been avoided compared to an all-biopsy approach. Group 3: the duodenal histology of 153 patients presenting to a separate iron deficiency anaemia clinic were retrospectively reviewed.ResultsIn group 1, serology was available in 361 (33.8 %) patients. In group 2, the sensitivity and negative predictive value (NPV) were 100 % and 100 % for Simtomax, 96.2 % and 98.9 % for IgA-TTG, and 84.6 % and 96.4 % for EMA respectively. In group 3, the duodenal histology found no causes for anaemia other than coeliac disease.ConclusionSimtomax had excellent diagnostic accuracy in iron deficiency anaemia and was comparable to conventional serology. Duodenal biopsy did not identify any causes other than coeliac disease for iron deficiency anaemia, suggesting that biopsy avoidance in Simtomax negative anaemic patients is unlikely to miss other anaemia-related pathologies. Due to its 100 % NPV, Simtomax could reduce unnecessary biopsies by 66 % if only those with a positive Simtomax were biopsied, potentially saving £3690/100 gastroscopies.Trial registrationThe group 2 study was retrospectively registered with clinicaltrials.gov. Trial registration date: 13th July 2016; Trial registration number: NCT02834429.
【 授权许可】
CC BY
© The Author(s). 2016
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311109458400ZK.pdf | 1067KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]
- [36]
- [37]
- [38]
- [39]
- [40]