期刊论文详细信息
International Journal of Behavioral Nutrition and Physical Activity
Validation of a new hand-held electronic data capture method for continuous monitoring of subjective appetite sensations
Methodology
Catherine Gibbons1  John Blundell1  Phillipa Caudwell1  Graham Finlayson1  Neil King2 
[1] Biopsychology Group, Institute of Psychological Sciences, University of Leeds, Leeds, UK;Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia;
关键词: Visual Analogue Scale;    Evaluation Questionnaire;    Visual Analogue Scale Scale;    Vertical Marker;    Appetite Sensation;   
DOI  :  10.1186/1479-5868-8-57
 received in 2010-11-03, accepted in 2011-06-08,  发布年份 2011
来源: Springer
PDF
【 摘 要 】

BackgroundWhen large scale trials are investigating the effects of interventions on appetite, it is paramount to efficiently monitor large amounts of human data. The original hand-held Electronic Appetite Ratings System (EARS) was designed to facilitate the administering and data management of visual analogue scales (VAS) of subjective appetite sensations. The purpose of this study was to validate a novel hand-held method (EARS II (HP® iPAQ)) against the standard Pen and Paper (P&P) method and the previously validated EARS.MethodsTwelve participants (5 male, 7 female, aged 18-40) were involved in a fully repeated measures design. Participants were randomly assigned in a crossover design, to either high fat (>48% fat) or low fat (<28% fat) meal days, one week apart and completed ratings using the three data capture methods ordered according to Latin Square. The first set of appetite sensations was completed in a fasted state, immediately before a fixed breakfast. Thereafter, appetite sensations were completed every thirty minutes for 4h. An ad libitum lunch was provided immediately before completing a final set of appetite sensations.ResultsRepeated measures ANOVAs were conducted for ratings of hunger, fullness and desire to eat. There were no significant differences between P&P compared with either EARS or EARS II (p > 0.05). Correlation coefficients between P&P and EARS II, controlling for age and gender, were performed on Area Under the Curve ratings. R2 for Hunger (0.89), Fullness (0.96) and Desire to Eat (0.95) were statistically significant (p < 0.05).ConclusionsEARS II was sensitive to the impact of a meal and recovery of appetite during the postprandial period and is therefore an effective device for monitoring appetite sensations. This study provides evidence and support for further validation of the novel EARS II method for monitoring appetite sensations during large scale studies. The added versatility means that future uses of the system provides the potential to monitor a range of other behavioural and physiological measures often important in clinical and free living trials.This study was registered as a clinical trial by Current Controlled Trials (Registration Number - ISRCTN47291569).

【 授权许可】

CC BY   
© Gibbons et al; licensee BioMed Central Ltd. 2011

【 预 览 】
附件列表
Files Size Format View
RO202311109095608ZK.pdf 565KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  文献评价指标  