期刊论文详细信息
Journal of Translational Medicine
Percutaneous irreversible electroporation for breast tissue and breast cancer: safety, feasibility, skin effects and radiologic–pathologic correlation in an animal study
Research
Sheng Li1  Peihong Wu1  Lujun Shen1  Qi Zeng1  Fei Chen2 
[1] Department of Medical Imaging and Interventional Radiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, 510060, Guangzhou, Guangdong, People’s Republic of China;Department of Ultrasonography, The Second Affiliated Hospital of Guangzhou Medical University, Guangzhou, People’s Republic of China;
关键词: Irreversible electroporation;    Breast;    Imaging;    Pathology;    Apoptosis;    Skin;   
DOI  :  10.1186/s12967-016-0993-7
 received in 2015-10-24, accepted in 2016-07-28,  发布年份 2016
来源: Springer
PDF
【 摘 要 】

BackgroundTo study the safety, feasibility and skin effects of irreversible electroporation (IRE) for breast tissue and breast cancer in animal models.MethodsEight pigs were used in this study. IRE was performed on the left breasts of the pigs with different skin–electrode distances, and the right breasts were used as controls. The electrodes were placed 1–8 mm away from the skin, with an electrode spacing of 1.5–2 cm. Imaging and pathological examinations were performed at specific time points for follow-up evaluation. Vital signs, skin damage, breast tissue changes and ablation efficacy were also closely observed. Eight rabbit models with or without VX2 breast tumor implantations were used to further assess the damage caused by and the repair of thin skin after IRE treatment for breast cancer. Contrast-enhanced ultrasound and elastosonography were used to investigate ablation efficacy and safety.ResultsDuring IRE, the color of the pig breast skin reversibly changed. When the skin–electrode distance was 3 mm, the breast skin clearly changed, becoming white in the center and purple in the surrounding region during IRE. One small purulent skin lesion was detected several days after IRE. When the skin–electrode distance was 5–8 mm, the breast skin became red during IRE. However, the skin architecture was normal when evaluated using gross pathology and hematoxylin-eosin staining. When the skin–electrode distance was 1 mm, skin atrophy and yellow glabrescence occurred in the rabbit breasts after IRE. When the skin–electrode distance was ≥5 mm, there was no skin damage in the rabbit model regardless of breast cancer implantation. After IRE, complete ablation of the targeted breast tissue or cancer was confirmed, and apoptosis was detected in the target tissue and outermost epidermal layer. In the ablated breasts of the surviving animals, complete mammary regeneration with normal skin and hair was observed. Furthermore, no massive fibrosis or mass formation were detected on ultrasound or through hematoxylin–eosin staining.ConclusionsAfter IRE, the skin architecture was well preserved when the skin–electrode distance was ≥5 mm. Moreover, breast regeneration occurred without mass formation or obvious fibrosis.

【 授权许可】

CC BY   
© The Author(s) 2016

【 预 览 】
附件列表
Files Size Format View
RO202311107677433ZK.pdf 3215KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  文献评价指标  
  下载次数:2次 浏览次数:0次