| Quantification of cervical spine muscle fat: a comparison between T1-weighted and multi-echo gradient echo imaging using a variable projection algorithm (VARPRO) | |
| Technical Advance | |
| Todd B Parrish1  James M Elliott2  Alfred Rademaker3  David M Walton4  | |
| [1] Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA;Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA;Department of Physical Therapy and Human Movement Sciences, Feinberg School of Medicine, Northwestern University, 645 North Michigan Avenue, Suite 1100 room 1139, 60611, Chicago, IL, USA;Department of Preventive Medicine, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA;School of Physical Therapy, Western University, London, Ontario, Canada; | |
| 关键词: Cervical Spine; Whiplash Injury; Concordance Coefficient; Muscular Fatty Infiltrate; Cervical Spine Magnetic Resonance Imaging; | |
| DOI : 10.1186/1471-2342-13-30 | |
| received in 2012-06-29, accepted in 2013-09-09, 发布年份 2013 | |
| 来源: Springer | |
PDF
|
|
【 摘 要 】
BackgroundPrevious data using T1-weighted MRI demonstrated neck muscle fat infiltration (MFI) in patients with poor functional recovery following whiplash. Such findings do not occur in those with milder symptoms of whiplash, chronic non-traumatic neck pain or healthy controls, suggesting traumatic factors play a role. Muscle degeneration could potentially represent a quantifiable marker of poor recovery, but the temporal constraints of running a T1-weighted sequence and performing the subsequent analysis for muscle fat may be a barrier for clinical translation. The purpose of this preliminary study was to evaluate, quantify and compare MFI for the cervical multifidus muscles with T1-weighted imaging and a more rapid quantitative 3D multi-echo gradient echo (GRE) Dixon based method in healthy subjects.Methods5 asymptomatic participants with no history of neck pain underwent cervical spine MRI with a Siemens 3 Tesla system. The muscle and fat signal intensities on axial spin-echo T1-weighted images were quantitatively classified for the cervical multifidii from C3-C7, bilaterally. Additional axial GRE Dixon based data for fat and water quantification were used for comparison via paired t-tests. Inter-tester reliability for fat and water measures with GRE images were examined using 1) Pearson’s Intra-class correlation coefficient 2) Bland-Altman Plots and 3) Lin’s-Concordance Coefficient. P < 0.05 was used to indicate significance.ResultsTotal mean (SD) MFI (C3-C7) for the multifidii obtained with T1-weighted imaging and GRE were 18.4% (3.3) (range 14-22%) and 18.8% (2.9) (range 15-22%), respectively. The Pearson correlation coefficients for inter-tester reliability on the GRE sequences for the C3-C7 multifidii ranged from .83 - .99, indicating high levels of agreement with segmental MFI measures. Bland-Altman Plots revealed all data points were within 2 SDs and concordance was established between 2-blinded raters, suggesting good agreement between two raters measuring fat and water with GRE imaging.ConclusionsResults of this preliminary study demonstrate reliability between 2 raters of varying experience for MRI analysis of MFI with 3D GRE MRI. The quantification of MFI for healthy cervical musculature is comparable to T1-weighted images. Inclusion of larger samples of symptomatic data and histological comparison with the reference standard biopsy is warranted.
【 授权许可】
CC BY
© Elliott et al.; licensee BioMed Central Ltd. 2013
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202311106552680ZK.pdf | 740KB |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
PDF