| Journal of Cardiovascular Magnetic Resonance | |
| Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus | |
| Research | |
| Marc R Dweck1  Shirjel Alam1  Michelle C Williams1  Lucy E Kershaw2  Saeed Mirsadraee3  Martin Connell3  Tom MacGillivray3  Calum Gray3  Giorgos Papanastasiou4  Scott IK Semple4  David E Newby4  | |
| [1] Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK;Christie Medical Physics and Engineering, The Christie NHS FT, Manchester, UK;Clinical Research Imaging Centre, University of Edinburgh,, Edinburgh, UK;Clinical Research Imaging Centre, University of Edinburgh,, Edinburgh, UK;Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK; | |
| 关键词: Cardiovascular magnetic resonance; Myocardial blood flow; Fermi modeling; Distributed parameter modeling; Fractional flow reserve; Invasive coronary angiography; | |
| DOI : 10.1186/s12968-015-0125-1 | |
| received in 2014-05-23, accepted in 2015-01-22, 发布年份 2015 | |
| 来源: Springer | |
PDF
|
|
【 摘 要 】
BackgroundMathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturation effect is evident during application of standard Fermi models in single bolus perfusion data. Dual bolus injection protocols have been suggested to eliminate saturation but are much less practical in the clinical setting. The distributed parameter model can also be used for absolute quantification but has not been applied in patients with coronary artery disease. We assessed whether distributed parameter modeling might be less dependent on arterial input function saturation than Fermi modeling in healthy volunteers. We validated the accuracy of each model in detecting reduced myocardial blood flow in stenotic vessels versus gold-standard invasive methods.MethodsEight healthy subjects were scanned using a dual bolus cardiac perfusion protocol at 3T. We performed both single and dual bolus analysis of these data using the distributed parameter and Fermi models. For the dual bolus analysis, a scaled pre-bolus arterial input function was used. In single bolus analysis, the arterial input function was extracted from the main bolus. We also performed analysis using both models of single bolus data obtained from five patients with coronary artery disease and findings were compared against independent invasive coronary angiography and fractional flow reserve. Statistical significance was defined as two-sided P value < 0.05.ResultsFermi models overestimated myocardial blood flow in healthy volunteers due to arterial input function saturation in single bolus analysis compared to dual bolus analysis (P < 0.05). No difference was observed in these volunteers when applying distributed parameter-myocardial blood flow between single and dual bolus analysis. In patients, distributed parameter modeling was able to detect reduced myocardial blood flow at stress (<2.5 mL/min/mL of tissue) in all 12 stenotic vessels compared to only 9 for Fermi modeling.ConclusionsComparison of single bolus versus dual bolus values suggests that distributed parameter modeling is less dependent on arterial input function saturation than Fermi modeling. Distributed parameter modeling showed excellent accuracy in detecting reduced myocardial blood flow in all stenotic vessels.
【 授权许可】
CC BY
© Papanastasiou et al.; licensee BioMed Central. 2015
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202311105856138ZK.pdf | 1485KB | ||
| Fig. 5 | 1739KB | Image | |
| Fig. 9 | 1857KB | Image | |
| 12951_2016_225_Article_IEq3.gif | 1KB | Image | |
| Fig. 6 | 889KB | Image | |
| 12951_2016_225_Article_IEq2.gif | 1KB | Image | |
| Fig. 4 | 756KB | Image | |
| Fig. 2 | 401KB | Image |
【 图 表 】
Fig. 2
Fig. 4
12951_2016_225_Article_IEq2.gif
Fig. 6
12951_2016_225_Article_IEq3.gif
Fig. 9
Fig. 5
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
PDF