Quantification of aortic stenosis diagnostic parameters: comparison of fast 3 direction and 1 direction phase contrast CMR and transthoracic echocardiography
Research
Lee C. Potter1  Adam V. Rich1  Jennifer A. Dickerson2  Debbie Scandling3  Yingmin Liu3  Matthew Smyke3  Rizwan Ahmad4  Subha V. Raman5  Orlando P. Simonetti6  Juliana Serafim da Silveira7  Carlos E. Rochitte8  Ning Jin9 
[1] Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, USA;Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University, Columbus, OH, USA;Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, USA;Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, USA;Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, USA;Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, USA;Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University, Columbus, OH, USA;Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, USA;Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University, Columbus, OH, USA;Department of Radiology, The Ohio State University, 460 W. 12th Avenue, room 320, 43210, Columbus, OH, USA;Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, USA;InCor Heart Institute, University of São Paulo Medical School, São Paulo, SP, Brazil;InCor Heart Institute, University of São Paulo Medical School, São Paulo, SP, Brazil;Siemens Healthcare, Erlangen, Germany;
关键词: Phase contrast imaging;    Multi-directional phase contrast CMR;    Bayesian model;    Aortic stenosis;    Transthoracic echocardiography;   
DOI  :  10.1186/s12968-017-0339-5
 received in 2016-10-19, accepted in 2017-02-10,  发布年份 2017
来源: Springer
PDF
【 摘 要 】

BackgroundAortic stenosis (AS) is a common valvular disorder, and disease severity is currently assessed by transthoracic echocardiography (TTE). However, TTE results can be inconsistent in some patients, thus other diagnostic modalities such as cardiovascular magnetic resonance (CMR) are demanded. While traditional unidirectional phase-contrast CMR (1Dir PC-CMR) underestimates velocity if the imaging plane is misaligned to the flow direction, multi-directional acquisitions are expected to improve velocity measurement accuracy. Nonetheless, clinical use of multidirectional techniques has been hindered by long acquisition times. Our goal was to quantify flow parameters in patients using 1Dir PC-CMR and a faster multi-directional technique (3Dir PC-CMR), and compare to TTE.MethodsTwenty-three patients were prospectively assessed with TTE and CMR. Slices above the aortic valve were acquired for both PC-CMR techniques and cine SSFP images were acquired to quantify left ventricular stroke volume. 3Dir PC-CMR implementation included a variable density sampling pattern with acceleration rate of 8 and a reconstruction method called ReVEAL, to significantly accelerate acquisition. 3Dir PC-CMR reconstruction was performed offline and ReVEAL-based image recovery was performed on the three (x, y, z) encoding pairs. 1Dir PC-CMR was acquired with GRAPPA acceleration rate of 2 and reconstructed online. CMR derived flow parameters and aortic valve area estimates were compared to TTE.ResultsReVEAL based 3Dir PC-CMR derived parameters correlated better with TTE than 1Dir PC-CMR. Correlations ranged from 0.61 to 0.81 between TTE and 1Dir PC-CMR and from 0.61 to 0.87 between TTE and 3Dir-PC-CMR. The correlation coefficients between TTE, 1Dir and 3Dir PC-CMR Vpeakwere 0.81 and 0.87, respectively. In comparison to ReVEAL, TTE slightly underestimates peak velocities, which is not surprising as TTE is only sensitive to flow that is parallel to the acoustic beam.ConclusionsBy exploiting structure unique to PC-CMR, ReVEAL enables multi-directional flow imaging in clinically feasible acquisition times. Results support the hypothesis that ReVEAL-based 3Dir PC-CMR provides better estimation of hemodynamic parameters in AS patients in comparison to 1Dir PC-CMR. While TTE can accurately measure velocity parallel to the acoustic beam, it is not sensitive to the other directions of flow. Therefore, multi-directional flow imaging, which encodes all three components of the velocity vector, can potentially outperform TTE in patients with eccentric or multiple jets.

【 授权许可】

CC BY   
© The Author(s). 2017

【 预 览 】
附件列表
Files Size Format View
RO202311105530202ZK.pdf 1414KB PDF download
Fig. 4 532KB Image download
【 图 表 】

Fig. 4

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  文献评价指标  
  下载次数:0次 浏览次数:0次