BMC Gastroenterology | |
Prospective cross-sectional study on faecal immunochemical tests: sex specific cut-off values to obtain equal sensitivity for colorectal cancer? | |
Research Article | |
Anneke A Bouman1  Chris JJ Mulder2  Sietze T van Turenhout2  Frank A Oort2  Jochim S Terhaar sive Droste2  Leo GM van Rossum3  Arjen P Visscher4  Veerle MH Coupé5  René WM van der Hulst6  Pieter Scholten7  Gerrit A Meijer8  | |
[1] Clinical Chemistry, VU University Medical Centre, Amsterdam, The Netherlands;Department of Gastroenterology and Hepatology, VU University Medical Centre, Amsterdam, The Netherlands;Department of Gastroenterology and Hepatology, VU University Medical Centre, Amsterdam, The Netherlands;Department for health evidence, Radboud University Medical Centre, Nijmegen, The Netherlands;Department of Gastroenterology and Hepatology, VU University Medical Centre, Amsterdam, The Netherlands;Gastroenterology and Hepatology, Kennemer Gasthuis, Haarlem, The Netherlands;Epidemiology and Biostatistics, VU University Medical Centre, Amsterdam, The Netherlands;Gastroenterology and Hepatology, Kennemer Gasthuis, Haarlem, The Netherlands;Gastroenterology and Hepatology, Sint Lucas Andreas Hospital, Amsterdam, The Netherlands;Pathology, VU University Medical Centre, Amsterdam, The Netherlands; | |
关键词: Colorectal cancer screening; Advanced adenoma; Fecal immunochemical test; Sex; | |
DOI : 10.1186/s12876-014-0217-7 | |
received in 2014-05-05, accepted in 2014-12-11, 发布年份 2014 | |
来源: Springer | |
【 摘 要 】
BackgroundFaecal immunochemical tests (FITs) are commonly used in colorectal cancer (CRC) screening. Diagnostic accuracy of FIT differs between males and females. This so far unexplained difference could result in a dissimilarity in screening outcome between both sexes. The aim of this study is to compare sensitivity and specificity of a FIT between males and females, and study potential explanatory variables.MethodsIn this cross-sectional study, data were prospectively collected. 3,022 subjects performed a FIT prior to complete colonoscopy. Sensitivity, specificity, and ROC curves were compared for both sexes. Potential explanatory variables of the relation between sensitivity and sex were explored.ResultsAt all cut-off values, FIT sensitivity for CRC was higher (range 13-23%) and specificity was lower (range 2-4%) in males compared to females. At 75 ng/ml, sensitivity for CRC was 93% in males compared to 71% in females (p = 0.03), and specificity was 90% in males compared to 93% in females (p = <0.05). For advanced adenomas, males had a slightly higher sensitivity and lower specificity (not significant). At 75 ng/ml, sensitivity for advanced adenomas was 33% in males compared to 29% in females (p = 0.46), and specificity was 93% in males compared to 95% in females (p = 0.22). ROC curves were similar for both sexes, and equal combinations of sensitivity and specificity could be achieved by adjusting the cut-off values. For CRC, the difference in sensitivity could not be explained by age or location of the tumour.ConclusionsFIT has a higher sensitivity and a lower specificity for CRC in males than in females. Equal test characteristics can be achieved by allowing separate cut-off values for both sexes. Location and age do not explain the observed differences in sensitivity.
【 授权许可】
CC BY
© van Turenhout et al.; licensee BioMed Central. 2014
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311104416722ZK.pdf | 745KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]