期刊论文详细信息
Environmental Health
Annoyance and activity disturbance induced by high-speed railway and conventional railway noise: a contrastive case study
Research
Zheng-Guang Li1  Guo-Qing Di1  Qi-Li Lin1  Jian Kang2 
[1] Institute of Environmental Pollution & Control Technology, Zhejiang University, 310058, Hangzhou, China;School of Architecture, University of Sheffield, Western Bank, 10 2TN, Sheffield, UK;
关键词: Noise descriptor;    High-speed railway;    Evaluation index;    Annoyance;    Activity disturbance;   
DOI  :  10.1186/1476-069X-13-12
 received in 2013-07-29, accepted in 2014-02-26,  发布年份 2014
来源: Springer
PDF
【 摘 要 】

BackgroundHigh-speed railway (HR, Electrified railway with service speed above 200 km/h.) noise and conventional railway (CR, Electrified railway with service speed under 200 km/h.) noise are different in both time and frequency domain. There is an urgent need to study the influence of HR noise and consequently, develop appropriate noise evaluation index and limits for the total railway noise including HR and CR noise.MethodsBased on binaural recording of HR and CR noises in a approximate semi-free field, noise annoyance and activity disturbance induced by maximal train pass-by events in China were investigated through laboratory subjective evaluation. 80 students within recruited 102 students, 40 males and 40 females, 23.9 ± 2.1 years old, were finally selected as the subjects. After receiving noise stimulus via headphone of a binaural audio playback system, subjects were asked to express the annoyance or activity disturbance due to railway noise at a 0-100 numerical scale.ResultsThe results show that with the same annoyance rating (A) or activity disturbance rating (D), the A-weighted equivalent sound pressure level (LAeq) of CR noise is approximately 7 dB higher than that of HR noise. Linear regression analysis between some acoustical parameters and A (or D) suggests that the coefficient of determination (R2) is higher with the instantaneous fast A-weighted sound pressure level (LAFmax) than that with LAeq. A combined acoustical parameter, LHC = 1.74LAFmax + 0.008LAFmax(Lp-LAeq), where Lp is the sound pressure level, was derived consequently, which could better evaluate the total railway noise, including HR and CR noise. More importantly, with a given LHC, the noise annoyance of HR and CR noise is the same.ConclusionsAmong various acoustical parameters including LHC and LAeq, A and D have the highest correlation with LHC. LHC has been proved to be an appropriate index to evaluate the total railway noise, including both HR and CR. However, it should be pointed out that this study provides suggestive evidence, rather than a final proof. Further study is expected to elucidate conclusions above by additional measurements.

【 授权许可】

CC BY   
© Di et al.; licensee BioMed Central Ltd. 2014

【 预 览 】
附件列表
Files Size Format View
RO202311104095831ZK.pdf 815KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  文献评价指标  
  下载次数:9次 浏览次数:8次