期刊论文详细信息
Cardiovascular Diabetology
Discriminant ratio and biometrical equivalence of measured vs. calculated apolipoprotein B100 in patients with T2DM
Original Investigation
Sylvie A Ahn1  Michel F Rousseau1  Michel P Hermans2 
[1] Cardiology Division, Cliniques universitaires St-Luc, and Institut de Recherche Expérimentale et Clinique (IREC), Université catholique de Louvain, Brussels, Belgium;Endocrinology & Nutrition, Cliniques universitaires St-Luc and Institut de Recherche Expérimentale et Clinique (IREC), Université catholique de Louvain, Brussels, Belgium;
关键词: ApoB;    LDL-C;    Non-HDL-C;    Discriminant ratio;    Type 2 diabetes;    Cardiovascular risk;   
DOI  :  10.1186/1475-2840-12-39
 received in 2012-12-18, accepted in 2013-02-22,  发布年份 2013
来源: Springer
PDF
【 摘 要 】

BackgroundApolipoprotein B100 (ApoB100) determination is superior to low-density lipoprotein cholesterol (LDL-C) to establish cardiovascular (CV) risk, and does not require prior fasting. ApoB100 is rarely measured alongside standard lipids, which precludes comprehensive assessment of dyslipidemia.ObjectivesTo evaluate two simple algorithms for apoB100 as regards their performance, equivalence and discrimination with reference apoB100 laboratory measurement.MethodsTwo apoB100-predicting equations were compared in 87 type 2 diabetes mellitus (T2DM) patients using the Discriminant ratio (DR). Equation 1: apoB100 = 0.65*non-high-density lipoprotein cholesterol + 6.3; and Equation 2: apoB100 = −33.12 + 0.675*LDL-C + 11.95*ln[triglycerides]. The underlying between-subject standard deviation (SDU) was defined as SDU = √ (SD2B - SD2W/2); the within-subject variance (Vw) was calculated for m (2) repeat tests as (Vw) = Σ(xj -xi)2/(m-1)), the within-subject SD (SDw) being its square root; the DR being the ratio SDU/SDW.ResultsAll SDu, SDw and DR’s values were nearly similar, and the observed differences in discriminatory power between all three determinations, i.e. measured and calculated apoB100 levels, did not reach statistical significance. Measured Pearson’s product-moment correlation coefficients between all apoB100 determinations were very high, respectively at 0.94 (measured vs. equation 1); 0.92 (measured vs. equation 2); and 0.97 (equation 1 vs. equation 2), each measurement reaching unity after adjustment for attenuation.ConclusionBoth apoB100 algorithms showed biometrical equivalence, and were as effective in estimating apoB100 from routine lipids. Their use should contribute to better characterize residual cardiometabolic risk linked to the number of atherogenic particles, when direct apoB100 determination is not available.

【 授权许可】

CC BY   
© Hermans et al; licensee BioMed Central Ltd. 2013

【 预 览 】
附件列表
Files Size Format View
RO202311103017210ZK.pdf 359KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  文献评价指标  
  下载次数:8次 浏览次数:1次