Neointimal dissection – a rare complication to endovascular treatment in grafts and stent grafts
Case Report
Lars Olaf Holmen1  Anne Sofie F. Larsen1  Shakil Aslam2 
[1] Radiology Department, Ostfold Hospital Trust, PB 300, Kalnesveien 300, 1714, Gralum, Norway;Surgery Department, Ostfold Hospital Trust, Gralum, Norway;
关键词: Neointima;    Fibrin sheet;    Dissection;    Graft;    Stent graft;    Endovascular treatment;   
DOI  :  10.1186/s42155-023-00401-x
 received in 2023-08-29, accepted in 2023-10-12,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundNeointima formation and hyperplasia in vascular grafts may lead to graft complications threatening the patency of the vascular reconstruction. A rare complication to endovascular treatment of grafts and stent grafts is dissection inside the graft.Case reportWe present here a case of a 69-year-old female with acute occlusion of the limb of an aorto-bifemoral graft for the third time, 16 years after the primary operation. As at the first two occasions, catheter-based intra-arterial thrombolysis was performed, but with residual stenosis inside the graft. During stent placement, dissection of the neointima or fibrin sheet occluded the inflow to the stent. The complication was resolved with placement of kissing stents.ConclusionsIt is important to recognize iatrogenic neointima dissection inside graft and stent grafts, as continued thrombolysis will not solve this, but increase the risk of hemorrhagic complications.

【 授权许可】

CC BY   
© Cardiovascular and Interventional Radiological Society of Europe (CIRSE) and Springer International Publishing AG 2023

【 预 览 】
附件列表
Files Size Format View
RO202311102888101ZK.pdf 3073KB PDF download
Fig. 3 1360KB Image download
MediaObjects/12951_2023_2117_MOESM1_ESM.docx 4908KB Other download
Fig. 1 127KB Image download
Fig. 6 1312KB Image download
【 图 表 】

Fig. 6

Fig. 1

Fig. 3

【 参考文献 】
  • [1]
  • [2]
  • [3]
  文献评价指标  
  下载次数:1次 浏览次数:1次