BMC Anesthesiology
Accuracy of an autocalibrated pulse contour analysis in cardiac surgery patients: a bi-center clinical trial
Research Article
Malte Metzner1  Jose Carbonell2  Carlos Ferrando2  Marina Soro2  Berthold Bein3  Jochen Renner4  Matthias Gruenewald4  Arne Carstens4  Markus Steinfath4  Ole Broch4  Jan Höcker4  Martin Albrecht4 
[1] Christian-Albrechts-University Kiel, Schleswig-Holstein, Germany;Department of Anaesthesiology and Critical Care, University Hospital Valencia, Avenida Blasco Ibanez 17, 46010, Valencia, Spain;Department of Anaesthesiology and Intensive Care Medicine, Asklepios Hospital St. Georg, Hamburg, Germany;Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Campus Kiel, Schwanenweg 21, D-24105, Kiel, Germany;
关键词: Cardiac index;    Pulse contour analysis;    Haemodynamic monitoring;    Transpulmonary thermodilution;   
DOI  :  10.1186/s12871-015-0153-2
 received in 2015-07-20, accepted in 2015-11-22,  发布年份 2015
来源: Springer
PDF
【 摘 要 】

BackgroundLess-invasive and easy to install monitoring systems for continuous estimation of cardiac index (CI) have gained increasing interest, especially in cardiac surgery patients who often exhibit abrupt haemodynamic changes. The aim of the present study was to compare the accuracy of CI by a new semi-invasive monitoring system with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB).MethodsSixty-five patients (41 Germany, 24 Spain) scheduled for elective coronary surgery were studied before and after CPB, respectively. Measurements included CI obtained by transpulmonary thermodilution (CITPTD) and autocalibrated semi-invasive pulse contour analysis (CIPFX). Percentage changes of CI were also calculated.ResultsThere was only a poor correlation between CITPTD and CIPFX both before (r2 = 0.34, p < 0.0001) and after (r2 = 0.31, p < 0.0001) CPB, with a percentage error (PE) of 62 and 49 %, respectively. Four quadrant plots revealed a concordance rate over 90 % indicating an acceptable correlation of trends between CITPTD and CIPFX before (concordance: 93 %) and after (concordance: 94 %) CPB. In contrast, polar plot analysis showed poor trending before and an acceptable trending ability of changes in CI after CPB.ConclusionsSemi-invasive CI by autocalibrated pulse contour analysis showed a poor ability to estimate CI compared with transpulmonary thermodilution. Furthermore, the new semi-invasive device revealed an acceptable trending ability for haemodynamic changes only after CPB.Trial registrationClinicalTrials.gov: NCT02312505 Date: 12.03.2012

【 授权许可】

CC BY   
© Broch et al. 2015

【 预 览 】
附件列表
Files Size Format View
RO202311102878494ZK.pdf 873KB PDF download
MediaObjects/13690_2023_1196_MOESM3_ESM.docx 26KB Other download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  文献评价指标  
  下载次数:6次 浏览次数:1次