Health and Quality of Life Outcomes | |
Development and validation of the self-management profile for type 2 diabetes (SMP-T2D) | |
Research | |
Ann Cameron1  Jennie H Best1  Mark Peyrot2  Donald M Bushnell3  Mona L Martin3  Donald L Patrick4  | |
[1] Amylin Pharmaceuticals, Inc, San Diego, CA, USA;Department of Sociology, Loyola University Maryland, Baltimore, MD, USA;Health Research Associates, Inc, Mountlake Terrace, WA, USA;Seattle Quality of Life Group, Department of Health Services, University of Washington, Seattle, WA, USA; | |
关键词: Physical Activity; Hypoglycemia; Exenatide; Sitagliptin; Physical Activity Behavior; | |
DOI : 10.1186/1477-7525-10-125 | |
received in 2012-02-09, accepted in 2012-09-22, 发布年份 2012 | |
来源: Springer | |
【 摘 要 】
BackgroundThis study evaluated the measurement properties of a newly developed instrument – the Self-Management Profile for Type 2 Diabetes (SMP-T2D).MethodsThe 18-item SMP-T2D assesses 12 constructs: level and perceived ease of performance in five self-care domains (blood glucose monitoring, medication-taking, healthy eating, being physically active, and coping), and two global constructs (ease of weight management, confidence with ability to manage diabetes). Validation analyses were based on two studies involving 240 patients with T2D, Study 1 (Clinicaltrials.gov #NCT00637273) with SMP-T2D administration supplemented by SMP-T2D retest one week later, and Study 2 (Clinical trials.gov #NCT00877890) with SMP-T2D administration supplemented by 24-week SMP-T2D follow-up after medication change. Validation included clinical indicators and measures of patient reported quality of life, psychological well-being and treatment outcomes.ResultsAll multi-item SMP-T2D measures showed acceptable internal consistency (alphas = 0.71 to 0.87); ten measures had test-retest reliability >0.75. Correlations among SMP-T2D measures and between SMP-T2D measures and validation measures, which were as hypothesized, provided evidence of convergent and discriminant validity. Scores for six SMP-T2D measures improved significantly during Study 2. Multiple regression analysis showed independent associations between change in SMP-T2D measures and change in trial outcomes from baseline to end-of-study.ConclusionsTwo studies provide preliminary evidence regarding the reliability, validity and responsiveness of the SMP-T2D. Further research on the utility of the instrument is needed.
【 授权许可】
CC BY
© Peyrot et al.; licensee BioMed Central Ltd. 2012
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311102209969ZK.pdf | 306KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]