BMC Cardiovascular Disorders | |
Long-term clinical outcomes of everolimus-eluting stent versus paclitaxel-eluting stent in patients undergoing percutaneous coronary interventions: a meta-analysis | |
Research Article | |
Xia Wang1  Bin Ge1  Min Meng1  Bei Gao1  Ri-na Sa1  Zheng-gang Bai2  | |
[1] Department of Pharmacy, Gansu Provincial Hospital, Donggang West Road No. 204, 730000, Lanzhou, Gansu, China;Evidence-Based Medicine Center, Lanzhou University, 730000, Lanzhou, Gansu, China; | |
关键词: Everolimus-eluting stent; Paclitaxel-eluting stent; Percutaneous coronary interventions; Systematic review; Meta-analysis; | |
DOI : 10.1186/s12872-016-0206-6 | |
received in 2015-07-18, accepted in 2016-01-29, 发布年份 2016 | |
来源: Springer | |
【 摘 要 】
BackgroundEverolimus -eluting stent (EES) is common used in patients undergoing percutaneous coronary interventions (PCI). Our purpose is to evaluate long-term clinical outcomes of everolimus -eluting stent (EES) versus paclitaxel-eluting stent (PES) in patients undergoing percutaneous coronaryinterventions (PCI) in randomized controlled trials (RCTs).MethodsWe searched Medline, EMBASE, Cochrane Library, CNKI, VIP and relevant websites (https://scholar-google-com.ezproxy.lib.usf.edu/) for articles to compare outcomes between everolimus-eluting stent and paclitaxel-eluting stent without language or date restriction. RCTs that compared the use of everolimus -eluting stent and paclitaxel-eluting stent in PCI were included. Variables relating to patient, study characteristics, and clinical endpoints were extracted. Meta-analysis was performed using RevMan 5.2 software.ResultsWe identified 6 published studies (from three randomized trials) more on everolimus-eluting stent (n = 3352) than paclitaxel-eluting (n = 1639), with follow-up duration ranging from 3, 4 and 5 years. Three-year outcomes of everolimus-eluting stent compared to paclitaxel-eluting were as following: the everolimus-eluting stent significantly reduced all-cause death (relative risk [RR]:0.63; 95 % confidence interval [CI]: 0.46. to 0.82), MACE (RR: 0.56; 95 % CI: 0.41 to 0.77), MI (RR: 0.64; 95 % CI: 0.48 to 0.86), TLR (RR: 0.72; 95 % CI: 0.59 to 0.88), ID-TLR (RR: 0.74; 95 % CI: 0.59 to 0.92) and ST (RR: 0.54; 95 % CI: 0.32 to 0.90). There was no difference in TVR between the everolimus-eluting and paclitaxel-eluting (RR: 0.76; 95 % CI: 0.58 to 1.10); Four-year outcomes of everolimus-eluting compared to paclitaxel-eluting: the everolimus-eluting significantly reduced MACE (RR: 0.44; 95 % CI: 0.18 to 0.98) and ID-TLR (RR: 0.47; 95 % CI: 0.23 to 0.97). There was no difference in MI (RR: 0.48; 95 % CI: 0.16 to 1.46), TLR (RR: 0.46; 95 % CI: 0.20 to1.04) and ST ((RR: 0.34; 95 % CI: 0.05 to 2.39). Five-year outcomes of everolimus-eluting stent compared to paclitaxel-eluting: There was no difference in ID-TLR (RR: 0.67; 95 % CI: 0.45 to 1.02) and ST (RR: 0.71; 95 % CI: 0.28 to1.80).ConclusionsIn the present meta-analysis, everolimus-eluting appeared to be safe and clinically effective in patients undergoing PCI in comparison to PES in 3-year clinical outcomes; there was similar no difference in reduction of ST between EES and PES in long-term(≥4 years) clinical follow-ups. Everolimus-eluting is more safety than paclitaxel-eluting in long-term clinical follow-ups, whether these effects can be applied to different patient subgroups warrants further investigation.
【 授权许可】
CC BY
© Meng et al. 2016
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311101245863ZK.pdf | 2589KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]
- [36]
- [37]
- [38]
- [39]
- [40]
- [41]
- [42]
- [43]
- [44]
- [45]
- [46]
- [47]
- [48]
- [49]
- [50]