Cardiovascular Ultrasound | |
Standardized ultrasound evaluation of carotid stenosis for clinical trials: University of Washington Ultrasound Reading Center | |
Research | |
Edward T Stutzman1  R Eugene Zierler1  Kirk W Beach1  Robert O Bergelin1  Jean F Primozich1  P Max Sevareid1  Daniel F Leotta1  | |
[1] Department of Surgery, D. Eugene Strandness Vascular Laboratory University of Washington, 98195, Seattle, Washington, USA; | |
关键词: Internal Carotid Artery; Common Carotid Artery; Carotid Stenosis; Carotid Artery Stenting; Peak Systolic Velocity; | |
DOI : 10.1186/1476-7120-8-39 | |
received in 2010-08-13, accepted in 2010-09-07, 发布年份 2010 | |
来源: Springer | |
【 摘 要 】
IntroductionSerial monitoring of patients participating in clinical trials of carotid artery therapy requires noninvasive precision methods that are inexpensive, safe and widely available. Noninvasive ultrasonic duplex Doppler velocimetry provides a precision method that can be used for recruitment qualification, pre-treatment classification and post treatment surveillance for remodeling and restenosis. The University of Washington Ultrasound Reading Center (UWURC) provides a uniform examination protocol and interpretation of duplex Doppler velocity measurements.MethodsDoppler waveforms from 6 locations along the common carotid and internal carotid artery path to the brain plus the external carotid and vertebral arteries on each side using a Doppler examination angle of 60 degrees are evaluated. The UWURC verifies all measurements against the images and waveforms for the database, which includes pre-procedure, post-procedure and annual follow-up examinations. Doppler angle alignment errors greater than 3 degrees and Doppler velocity measurement errors greater than 0.05 m/s are corrected.ResultsAngle adjusted Doppler velocity measurements produce higher values when higher Doppler examination angles are used. The definition of peak systolic velocity varies between examiners when spectral broadening due to turbulence is present. Examples of measurements are shown.DiscussionAlthough ultrasonic duplex Doppler methods are widely used in carotid artery diagnosis, there is disagreement about how the examinations should be performed and how the results should be validated. In clinical trails, a centralized reading center can unify the methods. Because the goals of research examinations are different from those of clinical examinations, screening and diagnostic clinical examinations may require fewer velocity measurements.
【 授权许可】
CC BY
© Beach et al; licensee BioMed Central Ltd. 2010
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311100945652ZK.pdf | 11621KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]