期刊论文详细信息
Cardiovascular Ultrasound
A longitudinal study on BIO14.6 hamsters with dilated cardiomyopathy: micro-echocardiographic evaluation
Research
Santolo Cozzolino1  Maria Paola Belfiore2  Daniela Berritto2  Claudia Rossi2  Salvatore Cappabianca2  Antonio Rotondo2  Roberto Grassi2  Francesca Iacobellis2  Ida Luisa Rotundo3  Gerardo Nigro3 
[1] Biotechnology Center, "A. Cardarelli" Hospital, Via Cardarelli 9, 80131, Napoli, Italy;Institute of Radiology, Second University of Naples (SUN), P.zza Miraglia 2, 80138, Napoli, Italy;Via Pietro Castellino 111, Telethon Institute of Genetics and Medicine (TIGEM), 80131, Napoli, Italy;
关键词: μ-US;    muscular dystrophy;    gene therapy;    animal model;   
DOI  :  10.1186/1476-7120-9-39
 received in 2011-07-12, accepted in 2011-12-08,  发布年份 2011
来源: Springer
PDF
【 摘 要 】

BackgroundIn recent years, several new technologies for small-animal imaging have been developed. In particular, the use of ultrasound in animal imaging has focused on the investigation of accessible biological structures such as the heart, of which it provides a morphological and functional assessment. The purpose of this study was to investigate the role of micro-ultrasonography (μ-US) in a longitudinal study on BIO14.6 cardiomyopathic hamsters treated with gene therapy.MethodsThirty hamsters were divided into three groups (n = 10): Group I, untreated BIO 14.6 hamsters; Group II, BIO 14.6 hamsters treated with gene therapy; Group III, untreated wild type (WT) hamsters. All hamsters underwent serial μ-US sessions and were sacrificed at predetermined time points.Resultsμ-US revealed: in Group I, progressive dilation of the left ventricle with a change in heart morphology from an elliptical to a more spherical shape, altered configuration of the mitral valve and subvalvular apparatus, and severe reduction in ejection fraction; in Group II, mild decrease in contractile function and ejection fraction; in Group III, normal cardiac chamber morphology and function. There was a negative correlation between the percentage of fibrosis observed at histology and the ejection fraction obtained on μ-echocardiography (Spearman r: -0.839; p < 0.001).ConclusionsAlthough histological examination remains indispensable for a conclusive diagnosis, high-frequency μ-echocardiography, thanks to the high spatial and contrast resolution, can be considered sufficient for monitoring therapeutic efficacy and/or the progression of dilated cardiomyopathy, providing an alternative tool for repeatable and noninvasive evaluation.

【 授权许可】

Unknown   
© Belfiore et al; licensee BioMed Central Ltd. 2011. This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

【 预 览 】
附件列表
Files Size Format View
RO202311100052597ZK.pdf 983KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  文献评价指标  
  下载次数:1次 浏览次数:0次