期刊论文详细信息
BMC Cardiovascular Disorders
Effects of HeartWare ventricular assist device on the von Willebrand factor: results of an academic Belgian center
Research Article
Jean-François Argacha1  Fatemeh Esmaeilzadeh2  Philippe van de Borne2  Aurélien Wauters2  Walter Wijns3 
[1] Department of Cardiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel (VUB), Brussels, Belgium;Department of Cardiology, Université Libre de Bruxelles (ULB), 808 Lennik Street, 1070, Brussels, Belgium;Laboratory of Haemostasis, Erasme Hospital, Université Libre de Bruxelles (ULB), Brussels, Belgium;
关键词: HeartWare;    Left ventricle assist device;    von Willebrand factor;    ADAMTS13;    Bleeding;   
DOI  :  10.1186/s12872-016-0334-z
 received in 2016-05-05, accepted in 2016-07-23,  发布年份 2016
来源: Springer
PDF
【 摘 要 】

BackgroundLeft Ventricular Assist Device (LVAD) is a promising therapy for patients with advanced heart failure (HF), but bleeding complications remain an important issue. Previous series show that acquired von Willebrand syndrome was present in up to 100 % of first generation LVAD recipients. We report the effects of new generation LVADs on vW factor (vWF) metabolism and activity in our center.MethodsFifteen LVAD recipients (HeartWare®, Framingham, MA, USA) were compared to 12 HF patients, matched for age and body mass index. vWF antigen and activity, as well as D-dimers, were measured on hemostasis analyzers. A vWF LVAD-induced alteration was evocated when the [vWF activity]/[vWF antigen] ratio was <0.6. ADAMTS13 and high molecular weight multimers of vWF were also assessed.ResultsLVAD recipients had similar levels of endothelial vWF production than the HF subjects (137 ± 14.5 vs. 147 ± 11.7 %; respectively, p = 0.611) but a decreased vWF activity (90 ± 11 vs. 132.6 ± 13 %; respectively, p = 0.017). [vWF activity]/[vWF antigen] ratio was 0.65 ± 0.02 in the LVAD recipients and 0.92 ± 0.06 in the subjects with HF (p = 0.001). ADAMTS13 activity was 80.3 ± 4.7 % in LVAD recipients and 96.2 ± 3.5 % in the HF patients (p = 0.016). LVAD patients disclosed markedly elevated D-dimers (3217.7 ± 735 vs. 680.6 ± 223.2 ng/mL FEU in the HF patients, p = 0.006). The LVAD patients experienced one major hemorrhagic event and one systemic thrombotic event during the median follow-up of 345 days.ConclusionsLVAD recipients achieved a new hemostatic equilibrium characterized by infrequent major hemorrhagic and thrombotic events, despite a mildly impaired vWF function and a markedly enhanced thrombin formation.Trial registrationISRCTN39517567

【 授权许可】

CC BY   
© The Author(s). 2016

【 预 览 】
附件列表
Files Size Format View
RO202311096979928ZK.pdf 751KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  文献评价指标  
  下载次数:11次 浏览次数:4次