BMC Cardiovascular Disorders | |
Vector flow mapping analysis of left ventricular energetic performance in healthy adult volunteers | |
Research Article | |
Keiichi Itatani1  Yasufumi Nakajima2  Sachiko Maeda3  Teiji Sawa3  Yoshifumi Naito3  Mao Kinoshita3  Koichi Akiyama3  Saeko Hamaoka3  Hideya Kato3  Atsushi Kainuma3  Maki Ishii3  Naotoshi Nakamura4  Tasuku Matsuyama5  | |
[1] Cardiovascular Surgery, Kyoto Prefectural University of Medicine, Kamigyo, Kyoto, Japan;Department of Anesthesiology, Kansai Medical University, Hirakata, Japan;Department of Anesthesiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, 602-8566, Kamigyo, Kyoto, Japan;Department of Statistical Genetics, Kyoto University, Kamigyo, Kyoto, Japan;Emergency Medicine, Kamigyo, Japan; | |
关键词: Vector flow mapping; Energy loss; Kinetic energy; Energetic performance index; Vortex; | |
DOI : 10.1186/s12872-016-0444-7 | |
received in 2016-08-24, accepted in 2016-12-15, 发布年份 2017 | |
来源: Springer | |
【 摘 要 】
BackgroundVector flow mapping, a novel flow visualization echocardiographic technology, is increasing in popularity. Energy loss reference values for children have been established using vector flow mapping, but those for adults have not yet been provided. We aimed to establish reference values in healthy adults for energy loss, kinetic energy in the left ventricular outflow tract, and the energetic performance index (defined as the ratio of kinetic energy to energy loss over one cardiac cycle).MethodsTransthoracic echocardiography was performed in fifty healthy volunteers, and the stored images were analyzed to calculate energy loss, kinetic energy, and energetic performance index and obtain ranges of reference values for these.ResultsMean energy loss over one cardiac cycle ranged from 10.1 to 59.1 mW/m (mean ± SD, 27.53 ± 13.46 mW/m), with a reference range of 10.32 ~ 58.63 mW/m. Mean systolic energy loss ranged from 8.5 to 80.1 (23.52 ± 14.53) mW/m, with a reference range of 8.86 ~ 77.30 mW/m. Mean diastolic energy loss ranged from 7.9 to 86 (30.41 ± 16.93) mW/m, with a reference range of 8.31 ~ 80.36 mW/m. Mean kinetic energy in the left ventricular outflow tract over one cardiac cycle ranged from 200 to 851.6 (449.74 ± 177.51) mW/m with a reference range of 203.16 ~ 833.15 mW/m. The energetic performance index ranged from 5.3 to 37.6 (18.48 ± 7.74), with a reference range of 5.80 ~ 36.67.ConclusionsEnergy loss, kinetic energy, and energetic performance index reference values were defined using vector flow mapping. These reference values enable the assessment of various cardiac conditions in any clinical situation.
【 授权许可】
CC BY
© The Author(s). 2017
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311096876666ZK.pdf | 1273KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]
- [36]
- [37]
- [38]