BMC Infectious Diseases | |
Pleural fluid soluble triggering receptor expressed on myeloid cells-1 as a marker of bacterial infection: a meta-analysis | |
Research Article | |
Hanssa Summah1  Ying-Gang Zhu1  Li-Li Tao1  Jie-Ming Qu2  Hong-Ni Jiang3  | |
[1] Department of Pulmonary Medicine, Huadong Hospital, Shanghai Medical College, Fudan University, Shanghai, China;Department of Pulmonary Medicine, Huadong Hospital, Shanghai Medical College, Fudan University, Shanghai, China;Department of Pulmonary Medicine, Huadong Hospital, Fudan University School of Medicine, Shanghai, China;Department of Pulmonary Medicine, Zhongshan Hospital, Shanghai Medical College, Fudan University, Shanghai, China; | |
关键词: Pleural Effusion; Pleural Fluid; Negative Likelihood Ratio; Positive Likelihood Ratio; Diagnostic Odds Ratio; | |
DOI : 10.1186/1471-2334-11-280 | |
received in 2011-04-24, accepted in 2011-10-20, 发布年份 2011 | |
来源: Springer | |
【 摘 要 】
BackgroundPleural infection is a common clinical problem. Its successful treatment depends on rapid diagnosis and early initiation of antibiotics. The measurement of soluble triggering receptor expressed in myeloid cells-1 (sTREM-1) level in pleural effusions has proven to be a valuable diagnostic tool for differentiating bacterial effusions from effusions of other etiologies. Herein, we performed a meta-analysis to assess the accuracy of pleural fluid sTREM-1 in the diagnosis of bacterial infection.MethodsWe searched Web of Knowledge and Medline from 1990 through March 2011 for studies reporting diagnostic accuracy data regarding the use of sTREM-1 in the diagnosis of bacterial pleural effusions. Pooled sensitivity and specificity and summary measures of accuracy and Q* were calculated.ResultsOverall, the sensitivity of sTREM-1was 78% (95% CI: 72%-83%); the specificity was 84% (95% CI: 80%-87%); the positive likelihood ratio was 6.0 (95% CI: 3.3-10.7); and the negative likelihood ratio was 0.22 (95% CI: 0.12-0.40). The area under the SROC curve for sTREM-1 was 0.92. Statistical heterogeneity and inconsistency were found for sensitivity (p = 0.015, χ2 = 15.73, I2 = 61.9%), specificity (p = 0.000, χ2 = 29.90, I2 = 79.9%), positive likelihood ratio (p = 0.000, χ2 = 33.09, I2 = 81.9%), negative likelihood ratio (p = 0.008, χ2 = 17.25, I2 = 65.2%), and diagnostic odds ratio (p = 0.000, χ2 = 28.49, I2 = 78.9%). A meta-regression analysis performed showed that the Quality Assessment of Diagnostic Accuracy Studies score (p = 0.3245; RDOR, 4.34; 95% CI, 0.11 to 164.01), the Standards for Reporting of Diagnostic Accuracy score (p = 0.3331; RDOR, 1.70; 95% CI, 0.44 to 6.52), lack of blinding (p = 0.7439; RDOR, 0.60; 95% CI, 0.01 to 33.80), and whether the studies were prospective or retrospective studies (p = 0.2068; RDOR, 7.44; 95% CI, 0.18 to 301.17) did not affect the test accuracy. A funnel plot for publication bias suggested a remarkable trend of publication bias.ConclusionsOur findings suggest that sTREM-1 has a good diagnostic accuracy and may provide a useful adjunctive tool for the diagnosis of bacterial pleural effusions. However, further studies are needed in order to identify any differences in the diagnostic performance of sTREM-1 of parapneumonic effusions and empyemas.
【 授权许可】
Unknown
© Summah et al; licensee BioMed Central Ltd. 2011. This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311096518580ZK.pdf | 520KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]