| BMC Musculoskeletal Disorders | |
| Visual detection of cortical breaks in hand joints: reliability and validity of high-resolution peripheral quantitative CT compared to microCT | |
| Research Article | |
| B. van Rietbergen1  A. van Tubergen2  P. Geusens3  J. de Jong4  A. Scharmga5  M. Peters5  J. van den Bergh6  R. Weijers7  D. Loeffen7  | |
| [1] Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands;Department of Medicine, division of Rheumatology, Maastricht University Medical Centre, P.O. Box 5800, NL-6202 AZ, Maastricht, The Netherlands;CAPHRI School for Public Health and Primary Care, Maastricht University, Maastricht, The Netherlands;Department of Medicine, division of Rheumatology, Maastricht University Medical Centre, P.O. Box 5800, NL-6202 AZ, Maastricht, The Netherlands;CAPHRI School for Public Health and Primary Care, Maastricht University, Maastricht, The Netherlands;Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium;Department of Medicine, division of Rheumatology, Maastricht University Medical Centre, P.O. Box 5800, NL-6202 AZ, Maastricht, The Netherlands;NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands;Department of Medicine, division of Rheumatology, Maastricht University Medical Centre, P.O. Box 5800, NL-6202 AZ, Maastricht, The Netherlands;NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands;CAPHRI School for Public Health and Primary Care, Maastricht University, Maastricht, The Netherlands;Department of Medicine, division of Rheumatology, Maastricht University Medical Centre, P.O. Box 5800, NL-6202 AZ, Maastricht, The Netherlands;NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands;Department of Internal Medicine, Viecuri Medical Center, Venlo, The Netherlands;Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium;Department of Radiology, Maastricht University Medical Centre, Maastricht, The Netherlands; | |
| 关键词: Imaging; Computed tomography; Hand; Bone; Rheumatoid arthritis; | |
| DOI : 10.1186/s12891-016-1148-y | |
| received in 2016-04-07, accepted in 2016-06-29, 发布年份 2016 | |
| 来源: Springer | |
PDF
|
|
【 摘 要 】
BackgroundTo study the reliability and validity of high-resolution peripheral quantitative CT (HR-pQCT) with microCT (μCT) as gold standard in the visual detection of cortical breaks in metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints.MethodsTen cadaveric fingers (10 MCP and 9 PIP joints) were imaged by HR-pQCT and μCT and visually analyzed by two independent readers. Intra- and interreader reliability were evaluated for the presence (yes/no, kappa statistics) and the total number (intraclass correlation coefficient, ICC) of cortical breaks. Sensitivity, specificity, positive and negative predictive value (PPV respectively NPV) of HR-pQCT in detecting cortical breaks were calculated.ResultsWith HR-pQCT, mean 149 cortical breaks were identified and with μCT mean 129 (p < 0.05). Intrareader reliability for the presence of a cortical break per quadrant was 0.52 (95 % CI 0.48–0.56) and 0.71 (95 % CI 0.67–0.75) for HR-pQCT and μCT, respectively, and for the total number of cortical breaks 0.61 (95 % CI 0.49–0.70) and 0.75 (95 % CI 0.68–0.82). Interreader reliability for the presence of a cortical break per quadrant was 0.37 (95 % CI 0.33–0.41) and 0.45 (95 % CI 0.41–0.49) for HR-pQCT and μCT, respectively, and for the number of cortical breaks 0.55 (95 % CI 0.43–0.65) and 0.54 (95 % CI 0.35–0.67). Sensitivity, specificity, PPV and NPV of HR-pQCT were 81.6, 64.0, 81.6, and 64 % respectively.ConclusionCortical breaks were commonly visualized in MCP and PIP joints with HR-pQCT and μCT. Reliability of both HR-pQCT and μCT was fair to moderate. HR-pQCT was highly sensitive to detect cortical breaks with μCT as gold standard.
【 授权许可】
CC BY
© The Author(s). 2016
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO202311094878738ZK.pdf | 1885KB |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
PDF