期刊论文详细信息
BMC Ophthalmology
The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: a meta-analysis
Research Article
Shiming Wang1  Xiaoming Gao1  Nana Qian1 
[1] Ningbo Aier Guangming Eye Hospital, 8 Huancheng north Road, 315020, Ningbo, China;
关键词: Ahmed glaucoma valve implant;    Baerveldt implant;    Refractory glaucoma;   
DOI  :  10.1186/s12886-016-0265-6
 received in 2015-11-10, accepted in 2016-05-28,  发布年份 2016
来源: Springer
PDF
【 摘 要 】

BackgroundThe purpose of this study was to compare the efficacy and tolerability of the Ahmed glaucoma valve (AGV) implant and the Baerveldt implant for the treatment of refractory glaucoma.MethodsWe comprehensively searched four databases, including PubMed, EMBASE, Web of Science, and the Cochrane Library databases, selecting the relevant studies. The continuous variables, namely, intraocular pressure reduction (IOPR) and a reduction in glaucoma medication, were pooled by the weighted mean differences (WMDs), and the dichotomous outcomes, including success rates and tolerability estimates, were pooled by the odds ratio (ORs).ResultsA total of 929 patients from six studies were included. The WMDs of the IOPR between the AGV implant and the Baerveldt implant were 1.58 [95 % confidence interval (CI): −2.99 to 6.15] at 6 months, −1.01 (95 % CI: −3.40 to 1.98) at 12 months, −0.54 (95 % CI: −4.89 to 3.82) at 24 months, and −0.47 (95 % CI: −3.29 to 2.35) at 36 months. No significant difference was detected between the two groups at any point in time. The pooled ORs comparing the AGV implant with the Baerveldt implant were 0.51 (95 % CI: 0.33 to 0.80) for the complete success rate and 0.67 (95 % CI: 0.50 to 0.91) for qualified success rate. The Baerveldt implant was associated with a reduction in glaucoma medication at −0.51 (95 % CI: −0.90 to −0.12). There were no significant differences between the AGV implant and the Baerveldt implant on the rates of adverse events.ConclusionsThe Baerveldt implant is more effective in both its surgical success rate and reducing glaucoma medication, but it is comparable to the AGV implant in lowering IOP. Both implants may have comparable incidences of adverse events.

【 授权许可】

CC BY   
© Wang et al. 2016

【 预 览 】
附件列表
Files Size Format View
RO202311094647308ZK.pdf 678KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  文献评价指标  
  下载次数:1次 浏览次数:0次