BMC Biotechnology | |
Engineering of the LukS-PV and LukF-PV subunits of Staphylococcus aureusPanton-Valentine leukocidin for Diagnostic and Therapeutic Applications | |
Methodology Article | |
Alan Cockayne1  Christopher Penfold1  Richard James1  Charles Emeka Okolie2  | |
[1] School of Molecular Medical Sciences, Centre for Biomolecular Sciences, University of Nottingham, University Park, NG7 2UH, Nottingham, UK;School of Molecular Medical Sciences, Centre for Biomolecular Sciences, University of Nottingham, University Park, NG7 2UH, Nottingham, UK;Department of Biological Sciences, College of Science and Engineering, Landmark University, Omu-Aran, Kwara State, Nigeria; | |
关键词: Staphylococcus aureus; Panton-Valentine leukocidin; Leukocytolytic exotoxin; Chromatography; Mass spectrometry; Immuno-therapy; | |
DOI : 10.1186/1472-6750-13-103 | |
received in 2013-09-09, accepted in 2013-10-31, 发布年份 2013 | |
来源: Springer | |
【 摘 要 】
BackgroundStaphylococcus aureus produces several toxins, including Panton-Valentine leukocidin (PVL). The involvement of PVL in primary skin infections, necrotizing pneumonia, musculoskeletal disorders, brain abscess, and other diseases, some of which are life-threatening, has been reported. Following expert opinion, we aimed to provide the tools for establishment of sequence-based diagnostics and therapeutics for those conditions. We engineered the synergistic S and F (LukS-PV and LukF-PV respectively) pro-toxin subunits from Staphylococcus aureus USA400 into separate expression E. coli BL21(DE3)-pLysS hosts.ResultsFollowing Nickel affinity chromatography (NAC), the F subunit came out without bands of impurity. The S sub-unit did not come off very pure after NAC thus necessitating further purification by size exclusion and ion-exchange chromatography. The purification plots showed that the BioLogic-LP and AKTA systems are reliable for following the progress of the chromatographic purification in real-time. Computer predicted Mw for the 6His-LukF-PV and 6His-LukS-PV were 35645.41 Da and 33530.04 Da respectively, while the mass spectrometry results were 35643.57 Da and 33528.34 Da respectively.ConclusionThe BioLogic-LP and AKTA systems are commendable for reliability and user-friendliness. As a recent work elsewhere also reported that a second round of chromatography was necessary to purify the S subunit after the first attempt, we speculate that the S subunit might contain yet unidentified motif(s) requiring further treatment. The purified S and F sub-units of PVL were supplied to the Nottingham Cancer Immunotherapy group who used them to establish sequence-based monoclonal antibodies for diagnostic and therapeutic uses targeting PVL.
【 授权许可】
CC BY
© Okolie et al.; licensee BioMed Central Ltd. 2013
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311094295476ZK.pdf | 1353KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]
- [36]
- [37]
- [38]
- [39]
- [40]
- [41]
- [42]
- [43]