Engineering of the LukS-PV and LukF-PV subunits of Staphylococcus aureusPanton-Valentine leukocidin for Diagnostic and Therapeutic Applications
Methodology Article
Alan Cockayne1  Christopher Penfold1  Richard James1  Charles Emeka Okolie2 
[1] School of Molecular Medical Sciences, Centre for Biomolecular Sciences, University of Nottingham, University Park, NG7 2UH, Nottingham, UK;School of Molecular Medical Sciences, Centre for Biomolecular Sciences, University of Nottingham, University Park, NG7 2UH, Nottingham, UK;Department of Biological Sciences, College of Science and Engineering, Landmark University, Omu-Aran, Kwara State, Nigeria;
关键词: Staphylococcus aureus;    Panton-Valentine leukocidin;    Leukocytolytic exotoxin;    Chromatography;    Mass spectrometry;    Immuno-therapy;   
DOI  :  10.1186/1472-6750-13-103
 received in 2013-09-09, accepted in 2013-10-31,  发布年份 2013
来源: Springer
PDF
【 摘 要 】

BackgroundStaphylococcus aureus produces several toxins, including Panton-Valentine leukocidin (PVL). The involvement of PVL in primary skin infections, necrotizing pneumonia, musculoskeletal disorders, brain abscess, and other diseases, some of which are life-threatening, has been reported. Following expert opinion, we aimed to provide the tools for establishment of sequence-based diagnostics and therapeutics for those conditions. We engineered the synergistic S and F (LukS-PV and LukF-PV respectively) pro-toxin subunits from Staphylococcus aureus USA400 into separate expression E. coli BL21(DE3)-pLysS hosts.ResultsFollowing Nickel affinity chromatography (NAC), the F subunit came out without bands of impurity. The S sub-unit did not come off very pure after NAC thus necessitating further purification by size exclusion and ion-exchange chromatography. The purification plots showed that the BioLogic-LP and AKTA systems are reliable for following the progress of the chromatographic purification in real-time. Computer predicted Mw for the 6His-LukF-PV and 6His-LukS-PV were 35645.41 Da and 33530.04 Da respectively, while the mass spectrometry results were 35643.57 Da and 33528.34 Da respectively.ConclusionThe BioLogic-LP and AKTA systems are commendable for reliability and user-friendliness. As a recent work elsewhere also reported that a second round of chromatography was necessary to purify the S subunit after the first attempt, we speculate that the S subunit might contain yet unidentified motif(s) requiring further treatment. The purified S and F sub-units of PVL were supplied to the Nottingham Cancer Immunotherapy group who used them to establish sequence-based monoclonal antibodies for diagnostic and therapeutic uses targeting PVL.

【 授权许可】

CC BY   
© Okolie et al.; licensee BioMed Central Ltd. 2013

【 预 览 】
附件列表
Files Size Format View
RO202311094295476ZK.pdf 1353KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  文献评价指标  
  下载次数:2次 浏览次数:0次