BMC Ophthalmology | |
Clinical efficacy of implantation of toric intraocular lenses with different incision positions: a comparative study of steep-axis incision and non-steep-axis incision | |
Research Article | |
Wenwen He1  Yu Du1  Xiangjia Zhu1  Yi Lu1  Jin Yang1  | |
[1] Department of Ophthalmology, Eye and Ear, Nose, and Throat Hospital of Fudan University, 83 Fenyang Road, 200031, Shanghai, People’s Republic of China;Key Laboratory of Myopia, Ministry of Health, Shanghai Medical College of Fudan University, 200031, Shanghai, People’s Republic of China;Shanghai Key Laboratory of Visual Impairment and Restoration, 200031, Shanghai, People’s Republic of China; | |
关键词: Cataract surgery; Astigmatism; Incision; Toric intraocular lens; Visual function; | |
DOI : 10.1186/s12886-017-0528-x | |
received in 2017-04-05, accepted in 2017-07-19, 发布年份 2017 | |
来源: Springer | |
【 摘 要 】
BackgroundTo compare the clinical outcomes after implantation of AcrySof Toric IOLs with different clear corneal incisions.MethodsSixty cataract patients with regular corneal astigmatism who underwent phacoemulsification combined with implantation of an AcrySof Toric IOL were enrolled. They were divided into two groups according to the position of the clear corneal incision: steep-axis and non-steep-axis. Main outcome measurements included visual acuity, residual astigmatism and changes of corneal astigmatism 3 months postoperatively. Deviation of IOL axis according to the re-calculation using the actual surgically induced astigmatism (SIA) and visual function 3 months after surgery were also evaluated.ResultsThe corneal astigmatism decreased significantly in steep-axis group 3 months postoperatively (P < 0.05). Besides, more patients in non-steep-axis group were with irregular corneal astigmatism after the surgery (43.33% vs 10%, P = 0.004). The deviation of IOL axis according to the re-calculation using the actual SIA was significantly larger in non-steep-axis group than that of steep-axis group (P < 0.001). Moreover, the postoperative visual function was better in eyes of steep-axis group in various measurements, including point spread function, modulation transfer function and high-order aberrations.ConclusionSteep-axis clear corneal incision could reduce the cylinder power of toric IOL and lower the chance of postoperative irregular astigmatism, which may consequently improve the postoperative visual quality.
【 授权许可】
CC BY
© The Author(s). 2017
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311093808339ZK.pdf | 480KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]