期刊论文详细信息
BMC Medical Imaging
Agreement of left ventricular mass in steady state free precession and delayed enhancement MR images: implications for quantification of fibrosis in congenital and ischemic heart disease
Research Article
David Erlinge1  Goran Olivecrona1  Henrik Engblom2  Marcus Carlsson2  Martin Ugander2  Hakan Arheden2  Sigurdur S Stephensen3 
[1] Department of Cardiology, Lund University and Lund University Hospital, Lund, Sweden;Department of Radiology and Physiology, Lund University and Lund University Hospital, Lund, Sweden;Department of Radiology and Physiology, Lund University and Lund University Hospital, Lund, Sweden;Department of Pediatric Cardiology, Lund University and Lund University Hospital, Lund, Sweden;
关键词: Infarct Size;    Left Ventricular Mass;    Steady State Free Precession;    Delay Enhancement;    Steady State Free Precession Sequence;   
DOI  :  10.1186/1471-2342-10-4
 received in 2009-08-18, accepted in 2010-01-24,  发布年份 2010
来源: Springer
PDF
【 摘 要 】

BackgroundLeft ventricular mass (LVM) is used when expressing infarct or fibrosis as a percentage of the left ventricle (LV). Quantification of LVM is interchangeably carried out in cine steady state free precession (SSFP) and delayed enhancement (DE) magnetic resonance imaging (MRI). However, these techniques may yield different LVM. Therefore, the aim of the study was to compare LVM determined by SSFP and DE MRI in patients and determine the agreement with these sequences with ex vivo data in an experimental animal model.MethodsEthics committees approved human and animal studies. Informed written consent was obtained from all patients. SSFP and DE images were acquired in 60 patients (20 with infarction, 20 without infarction and 20 pediatric patients). Ex vivo MRI was used as reference method for LVM in 19 pigs and compared to in vivo SSFP and DE.ResultsLVM was greater in SSFP than in DE (p < 0.001) with a bias of 5.0 ± 6.7% in humans (r2 = 0.98), and a bias of 7.3 ± 6.7% (p < 0.001) in pigs (r2 = 0.83). Bias for SSFP and DE images compared to ex vivo LVM was -0.2 ± 9.0% and -7.7 ± 8.5% respectively.ConclusionsLVM was higher when measured with SSFP compared to DE. Thus, the percentage infarction of the LV will differ if SSFP or DE is used to determine LVM. There was no significant difference between SSFP and ex vivo LVM suggesting that SSFP is more accurate for LVM quantification. To avoid intrinsic error due to the differences between the sequences, we suggest using DE when expressing infarct as a percentage of LVM.

【 授权许可】

Unknown   
© Stephensen et al; licensee BioMed Central Ltd. 2010. This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

【 预 览 】
附件列表
Files Size Format View
RO202311092054858ZK.pdf 1105KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  文献评价指标  
  下载次数:1次 浏览次数:0次