BMC Medical Imaging | |
A computer aided measurement method for unstable pelvic fractures based on standardized radiographs | |
Research Article | |
Jing-xin Zhao1  Hai-long Du2  Li-hai Zhang2  Li-ning Zhang2  Li-cheng Zhang2  Pei-fu Tang2  Xiu-yun Su3  Zhe Zhao4  | |
[1] Department of Orthopedics, Chinese PLA 82nd Hospital, No.100 East Jiankang Road, Qinghe District, 223001, Huai’an, Jiangsu Province, People’s Republic of China;Department of Orthopedics, Chinese PLA General Hospital, No.28 Fuxing Road, 100853, Beijing, Haidian District, People’s Republic of China;Department of Orthopedics, Chinese PLA General Hospital, No.28 Fuxing Road, 100853, Beijing, Haidian District, People’s Republic of China;Department of Orthopedics, Chinese PLA General Hospital, No.28 Fuxing Road, 100853, Beijing, Haidian District, People’s Republic of China;Department of Orthopedics, Affiliated Hospital of the Academy of Military Medical Sciences, No.8 Dongdajie Road, 100071, Beijing, People’s Republic of China;Department of Orthopedics, Chinese PLA General Hospital, No.28 Fuxing Road, 100853, Beijing, Haidian District, People’s Republic of China;Department of Orthopedics, Beijing Tsinghua Chang Gung Hospital, No.1 Block Tiantongyuan North, 102218, Beijing, People’s Republic of China; | |
关键词: Unstable pelvic fractures; Radiographic assessment; Software-based measurement; Reliability study; | |
DOI : 10.1186/s12880-015-0084-x | |
received in 2015-05-23, accepted in 2015-09-21, 发布年份 2015 | |
来源: Springer | |
【 摘 要 】
BackgroundTo set up a method for measuring radiographic displacement of unstable pelvic ring fractures based on standardized X-ray images and then test its reliability and validity using a software-based measurement technique.MethodsTwenty-five patients that were diagnosed as AO/OTA type B or C pelvic fractures with unilateral pelvis fractured and dislocated were eligible for inclusion by a review of medical records in our clinical centre. Based on the input pelvic preoperative CT data, the standardized X-ray images, including inlet, outlet, and anterior-posterior (AP) radiographs, were simulated using Armira software (Visage Imaging GmbH, Berlin, Germany). After representative anatomic landmarks were marked on the standardized X-ray images, the 2-dimensional (2D) coordinates of these points could be revealed in Digimizer software (Model: Mitutoyo Corp., Tokyo, Japan). Subsequently, we developed a formula that indicated the translational and rotational displacement patterns of the injured hemipelvis. Five separate observers calculated the displacement outcomes using the established formula and determined the rotational patterns using a 3D-CT model based on their overall impression. We performed 3D reconstruction of all the fractured pelvises using Mimics (Materialise, Haasrode, Belgium) and determined the translational and rotational displacement using 3-matic suite. The interobserver reliability of the new method was assessed by comparing the continuous measure and categorical outcomes using intraclass correlation coefficient (ICC) and kappa statistic, respectively.ResultThe interobserver reliability of the new method for translational and rotational measurement was high, with both ICCs above 0.9. Rotational outcome assessed by the new method was the same as that concluded by 3-matic software. The agreement for rotational outcome among orthopaedic surgeons based on overall impression was poor (kappa statistic, 0.250 to 0.426). Compared with the 3D reconstruction outcome, the interobserver reliability of the formula method for translational and rotational measures was perfect with both ICCs more than 0.9.ConclusionsThe new method for measuring displacement using a formula was reliable, and could minimise the measurement errors and maximise the precision of pelvic fracture description. Furthermore, this study was useful for standardising the operative plan and establishing a theoretical basis for robot-assisted pelvic fracture surgery based on 2-D radiographs.
【 授权许可】
CC BY
© Zhao et al. 2015
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311091987405ZK.pdf | 1732KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]