期刊论文详细信息
BMC Pulmonary Medicine
Diagnostic accuracy of nasal nitric oxide for establishing diagnosis of primary ciliary dyskinesia: a meta-analysis
Research Article
Panayiotis Kouis1  Stefania I. Papatheodorou1  Panayiotis K. Yiallouros2 
[1] Cyprus International Institute for Environmental & Public Health in Association with Harvard School of Public Health, Cyprus University of Technology, 95 Irenes Street, 3041, Limassol, Cyprus;Cyprus International Institute for Environmental & Public Health in Association with Harvard School of Public Health, Cyprus University of Technology, 95 Irenes Street, 3041, Limassol, Cyprus;Department of Pediatrics, Hospital “Archbishop Makarios III”, Nicosia, Cyprus;
关键词: Primary Ciliary Dyskinesia;    Nitric oxide;    Kartagener syndrome;    Diagnosis;   
DOI  :  10.1186/s12890-015-0147-3
 received in 2015-06-17, accepted in 2015-11-19,  发布年份 2015
来源: Springer
PDF
【 摘 要 】

BackgroundTo date, diagnosis of Primary Ciliary Dyskinesia (PCD) remains difficult and challenging. We systematically evaluated the diagnostic performance of nasal Nitric Oxide (nNO) measurement for the detection of PCD, using either velum-closure (VC) or non-velum-closure (non-VC) techniques.MethodsAll major electronic databases were searched from inception until March 2015 using appropriate terms. The sensitivity and specificity of nNO measurement was calculated in PCD patients diagnosed by transmission electron microscopy, high speed video-microscopy or genetic testing. Summary receiver operating characteristic (HSROC) curves were drawn using the parameters of the fitted models.ResultsTwelve studies provided data for 13 different populations, including nine case–control (n = 793) and four prospective cohorts (n = 392). The overall sensitivity of nNO measured by VC techniques was 0.95 (95 % CI 0.91–0.97), while specificity was 0.94 (95 % CI 0.88–0.97). The positive likelihood ratio (LR+) of the test was 15.8 (95 % CI 8.1–30.6), whereas the negative likelihood ratio (LR-) was 0.06 (95 % CI 0.04–0.09). For non-VC techniques, the overall sensitivity of nNO measurement was 0.93 (95 % CI 0.89–0.96) whereas specificity was 0.95 (95 % CI 0.82–0.99). The LR+ of the test was 18.5 (95 % CI 4.6–73.8) whereas the LR- was 0.07 (95 % CI 0.04–0.12).ConclusionsDiagnostic accuracy of nNO measurement both with VC and non-VC maneuvers is high and can be effectively employed in the clinical setting to detect PCD even in young children, thus potentiating early diagnosis. Measurement of nNO merits to be part of a revised diagnostic algorithm with the most efficacious combination of tests to achieve PCD diagnosis.

【 授权许可】

CC BY   
© Kouis et al. 2015

【 预 览 】
附件列表
Files Size Format View
RO202311091887186ZK.pdf 1122KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  文献评价指标  
  下载次数:2次 浏览次数:1次