期刊论文详细信息
BMC Musculoskeletal Disorders
Dual-energy computed tomography has limited sensitivity for non-tophaceous gout: a comparison study with tophaceous gout
Research Article
Mara McAdams-DeMarco1  Tracie Kurano2  Janet W. Maynard2  Alan N. Baer2  Uma J. Thakur3  Gaurav K. Thawait3  Elliot K. Fishman3  John A. Carrino3  Matthew K. Fuld4 
[1] Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, MD, Baltimore, USA;Department of Medicine (Rheumatology), Johns Hopkins University School of Medicine, 5200 Eastern Avenue, Suite 4000, Mason Lord Center Tower, 21224, Baltimore, MD, USA;Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, MD, Baltimore, USA;Siemens Medical Solutions USA Inc., Malvern, PA, USA;
关键词: Gout;    Dual-energy computed tomography;    Imaging;    Diagnosis;    Tophaceous gout;    Non-tophaceous gout;   
DOI  :  10.1186/s12891-016-0943-9
 received in 2015-12-27, accepted in 2016-02-12,  发布年份 2016
来源: Springer
PDF
【 摘 要 】

BackgroundDual-energy computed tomography (DECT) is a new diagnostic tool for gout, but its sensitivity has not been established. Our goal was to assess the sensitivity of DECT for the detection of monosodium urate (MSU) deposits in non-tophaceous and tophaceous gout, both at the level of the patient and that of the individual joint or lesion.MethodsDECT was performed on 11 patients with crystal-proven non-tophaceous gout and 10 with tophaceous gout and included both the upper and lower extremities in 20/21 patients. DECT images were simultaneously acquired at 80 and 140 kV and then processed on a workstation with proprietary software using a two-material decomposition algorithm. MSU deposits were color coded as green by the software and fused onto grey-scale CT images. The number and location of these deposits was tallied independently by two DECT-trained radiologists blinded to the clinical characteristics of the patient. Sensitivity of DECT was defined as the proportion of patients with a confirmed diagnosis of gout which was correctly identified as such by the imaging technique. All patients provided informed consent to participate in this IRB-approved study.ResultsMSU deposits were detected by DECT in ≥1 joint area in 7/11 (64 %) patients with non-tophaceous gout, but were only detected in 3/12 (25 %) joints proven by aspiration to be affected with gout. Inclusion of the upper extremity joints in the scanning protocol did not improve sensitivity. All 10 patients with tophaceous gout had MSU deposits evident by DECT. The sensitivity of DECT for individual gouty erosions was assessed in 3 patients with extensive foot involvement. MSU deposits were detected by DECT within or immediately adjacent to 13/26 (50 %) erosions.ConclusionsA DECT protocol that includes all lower extremity joints has moderate sensitivity in non-tophaceous and high sensitivity in tophaceous gout. However, DECT has lower sensitivity when restricted to individual crystal-proven gouty joints in non-tophaceous disease or individual erosive lesions in tophaceous gout. The detection of MSU deposits by DECT relates to their size and density and the detection parameters of the DECT scanner and adjustment of the latter might improve sensitivity.

【 授权许可】

CC BY   
© Baer et al. 2016

【 预 览 】
附件列表
Files Size Format View
RO202311091170037ZK.pdf 1508KB PDF download
【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  文献评价指标  
  下载次数:14次 浏览次数:2次