BMC Genomics | |
Correcting for intra-experiment variation in Illumina BeadChip data is necessary to generate robust gene-expression profiles | |
Research Article | |
Andrew H Sims1  J Michael Dixon2  E Jane Macaskill2  Jeremy S Thomas2  Lorna Renshaw2  John MS Bartlett3  Vicky S Sabine3  Jano I van Hemert4  Robert R Kitchen5  | |
[1] Applied Bioinformatics of Cancer Group, Edinburgh Cancer Research Centre, Institute of Genetics and Molecular Medicine, Crewe Road South, EH4 2XR, Edinburgh, Edinburgh, UK;Breast Cancer Research Group, Western General Hospital, Crewe Road South, EH4 2XU, Edinburgh, UK;Endocrine Cancer Group, Edinburgh Cancer Research Centre, Institute of Genetics and Molecular Medicine, Crewe Road South, EH4 2XR, Edinburgh, UK;School of Informatics, University of Edinburgh, 10 Crichton Street, EH8 9AB, Edinburgh, UK;School of Physics, University of Edinburgh, 10 Crichton Street, EH8 9AB, Edinburgh, UK; | |
关键词: Everolimus; Quantile Normalisation; Batch Effect; Batch Correction; Primary Breast Tumour Sample; | |
DOI : 10.1186/1471-2164-11-134 | |
received in 2009-11-24, accepted in 2010-02-24, 发布年份 2010 | |
来源: Springer | |
【 摘 要 】
BackgroundMicroarray technology is a popular means of producing whole genome transcriptional profiles, however high cost and scarcity of mRNA has led many studies to be conducted based on the analysis of single samples. We exploit the design of the Illumina platform, specifically multiple arrays on each chip, to evaluate intra-experiment technical variation using repeated hybridisations of universal human reference RNA (UHRR) and duplicate hybridisations of primary breast tumour samples from a clinical study.ResultsA clear batch-specific bias was detected in the measured expressions of both the UHRR and clinical samples. This bias was found to persist following standard microarray normalisation techniques. However, when mean-centering or empirical Bayes batch-correction methods (ComBat) were applied to the data, inter-batch variation in the UHRR and clinical samples were greatly reduced. Correlation between replicate UHRR samples improved by two orders of magnitude following batch-correction using ComBat (ranging from 0.9833-0.9991 to 0.9997-0.9999) and increased the consistency of the gene-lists from the duplicate clinical samples, from 11.6% in quantile normalised data to 66.4% in batch-corrected data. The use of UHRR as an inter-batch calibrator provided a small additional benefit when used in conjunction with ComBat, further increasing the agreement between the two gene-lists, up to 74.1%.ConclusionIn the interests of practicalities and cost, these results suggest that single samples can generate reliable data, but only after careful compensation for technical bias in the experiment. We recommend that investigators appreciate the propensity for such variation in the design stages of a microarray experiment and that the use of suitable correction methods become routine during the statistical analysis of the data.
【 授权许可】
Unknown
© Kitchen et al; licensee BioMed Central Ltd. 2010. This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202311091120539ZK.pdf | 4690KB | download |
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]
- [36]
- [37]
- [38]
- [39]
- [40]
- [41]
- [42]