期刊论文详细信息
Frontiers in Chemistry
Separation and flow cytometry analysis of microplastics and nanoplastics
Chemistry
Jingjing Li1  Zixing Zhang1  Xian Zhang1  Guohui Zhang2  Fuyi Huang3 
[1] Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, China;Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, China;College of Life Sciences, Fujian Agriculture and Forestry University, Fuzhou, China;Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, China;University of Chinese Academy of Sciences, Beijing, China;
关键词: counting region;    flow cytometry;    microplastics;    multistage filtration;    nanoplastics;    Nile Red;   
DOI  :  10.3389/fchem.2023.1201734
 received in 2023-04-07, accepted in 2023-08-28,  发布年份 2023
来源: Frontiers
PDF
【 摘 要 】

In recent years, the utilization of flow cytometry for quantitative microplastic analysis has gained prominence. However, the current methods have some drawbacks that need to be improved. The present study aims to enhance the flow cytometry detection protocols for Nile red (NR) stained microplastics, facilitating distinct microplastic and nanoplastic enumeration. By elevating dimethyl sulfoxide (DMSO) concentration to 20%–30% within the solution, NR solubility improved and agglomeration reduced. The analysis of 26 replicates of polystyrene (PS) liquid samples through four distinct dot plots highlighted the superior accuracy of dot plots integrating yellow fluorescence. Through systematic staining of varying NR concentrations across three microplastic liquid samples (polyethylene terephthalate, polyethylene, and polypropylene), the optimal staining concentration was determined to be 15–20 μg/mL. The distributions of agglomerated NR and NR stained PS under two scenarios—dissolved NR and partially agglomerated NR—were compared. Results showed their distinct distributions within the side scatter versus yellow fluorescence dot plot. Counting results from gradient-diluted PS liquid samples revealed a microplastic detection lower limit of 104 particles/mL, with an optimal concentration range of 105–106 particles/mL. Flow cytometric assessment of PS microspheres spanning 150 nm to 40 μm indicated a 150 nm particle size detection minimum. Our investigation validated the efficacy of NR staining and subsequent flow cytometry analysis across eleven types of microplastics. Separation and concentration of microplastics (1.0–50.0 μm) and nanoplastics (0.2–1.0 μm) were achieved via sequential sieving through 50, 1.0, and 0.2 μm filter membranes. We used a combination of multiple filtration steps and flow cytometry to analyze microplastics and nanoplastics in nine simulated water samples. Our results showed that the combined amount of microplastics (1.0–50.0 μm) and nanoplastics (0.2–1.0 μm) after filtration had a ratio of 0.80–1.19 compared to the total microplastic concentration before filtration. This result confirms the practicality of our approach. By enhancing flow cytometry-based microplastic and nanoplastic detection protocols, our study provides pivotal technical support for research concerning quantitative toxicity assessment of microplastic and nanoplastic pollution.

【 授权许可】

Unknown   
Copyright © 2023 Li, Huang, Zhang, Zhang and Zhang.

【 预 览 】
附件列表
Files Size Format View
RO202310122224868ZK.pdf 6279KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:1次