期刊论文详细信息
BMC Ophthalmology
Validity of a novel optical coherence tomography angiography flow index in a cohort of primary open angle glaucoma
Research
Ragai Hatata1  Sherin Sadek1  Ahmed Ameen Ismail1  Mahmoud Kamal1 
[1] Department of Ophthalmology, Faculty of Medicine, Fayoum University, Al Fayoum, Egypt;
关键词: Optical coherence tomography angiography;    Mathematical model;    Flow index;    Glaucoma;    Hagen-Poiseuille law;   
DOI  :  10.1186/s12886-023-03108-8
 received in 2023-02-02, accepted in 2023-08-21,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundVascular mechanisms are implicated in many ocular diseases. Therefore, different vascular imaging modalities are used in management of such conditions. Optical coherence tomography angiography (OCTA) has high spatial resolution and segmentable 3D volumetric sampling enabling isolation of retinal and peripapillary vascular beds. However, OCTA only indirectly derives quantitative flow data i.e. velocimetry through methods and algorithms liable to limitations like signal saturation. This study introduces and validates novel mathematical OCTA flow indices that may compensate for some OCTA velocimetric limitations.MethodsThirty-seven eyes of 23 POAG patients were included. Each underwent baseline and follow-up assessment one month thereafter. Assessment comprised full ophthalmological examination, intraocular pressure (IOP), systemic arterial blood pressure (SABP) and OCTA macula and ONH. Angiograms were processed using ImageJ to calculate OCTA intensity-based flow indices (FIOs), for superficial vascular plexus (SVP), deep vascular plexus (DVP) and optic nerve head vascular plexus (ONH-RPC), i.e. SFIO, DFIO and ONHFIO respectively. Mean ocular perfusion pressure (MOPP) was calculated using IOP and SABP. OCTA vascular densities (VD) and MOPP were used to calculate three respective mathematical flow indices (FIMs) for SVP, DVP and ONH-RPC, based on Hagen-Poiseuille law, i.e. SFIM, DFIM, ONHFIM respectively. Pearson test was used for correlation between the two sets of indices. Intraclass correlation coefficient (ICC) was tested for baseline and follow-up values for each index.ResultsThere was positive correlation between the three FIMs and their respective FIOs at baseline and follow-up ranging between high and moderate. Correlation coefficients (CCs) were 0.773 and 0.609 for SFIM and SFIO P-value < 0.001, 0.829 and 0.624 for DFIM and DFIO P-value < 0.001 and 0.516 and 0.737 for ONHFIM P-value = 0.001 for baseline and follow-up respectively. ICCs were 0.772 P-value < 0.001, 0.328 P-value = 0.022 and 0.888 P-value < 0.001 for SFIM, DFIM and ONHFIM respectively. For SFIO, DFIO and ONHFIO, ICCs were 0.420 P-value = 0.004, 0.079 P-value = 0.320 and 0.833 P-value < 0.001 respectively.ConclusionThe novel FIMs are reliable alternatives to FIOs and may compensate for OCTA signal saturation in extremes of MOPP. SFIM and ONHFIM showed high ICCs with excellent reliability. While DFIM demonstrated low ICC indicating poor reliability, it still performed better than its corresponding DFIO.

【 授权许可】

CC BY   
© BioMed Central Ltd., part of Springer Nature 2023

【 预 览 】
附件列表
Files Size Format View
RO202310119714515ZK.pdf 2181KB PDF download
Fig. 1 142KB Image download
13690_2023_1170_Article_IEq115.gif 1KB Image download
Fig. 1 682KB Image download
MediaObjects/42004_2023_1000_MOESM6_ESM.pdf 1742KB PDF download
Fig. 5 1051KB Image download
Fig. 2 345KB Image download
Fig. 1 28KB Image download
Fig. 4 186KB Image download
13690_2023_1170_Article_IEq138.gif 1KB Image download
Fig. 3 1045KB Image download
Fig. 4 557KB Image download
MediaObjects/41408_2023_908_MOESM2_ESM.pdf 3090KB PDF download
Fig. 3 82KB Image download
Fig. 5 1272KB Image download
MediaObjects/13046_2023_2830_MOESM2_ESM.docx 47KB Other download
【 图 表 】

Fig. 5

Fig. 3

Fig. 4

Fig. 3

13690_2023_1170_Article_IEq138.gif

Fig. 4

Fig. 1

Fig. 2

Fig. 5

Fig. 1

13690_2023_1170_Article_IEq115.gif

Fig. 1

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  文献评价指标  
  下载次数:9次 浏览次数:0次