期刊论文详细信息
BMC Medical Imaging
Differentiating tumour progression from pseudoprogression in glioblastoma patients: a monoexponential, biexponential, and stretched-exponential model-based DWI study
Research
Yuan-Cheng Liu1  Jiang-Yong Liu1  Di Wang1  Xin-Feng Liu1  Dan Liao2 
[1] Department of Radiology, Guizhou Provincial People’s Hospital, 550002, Guiyang, Guizhou, China;Department of Radiology, Guizhou Provincial People’s Hospital, 550002, Guiyang, Guizhou, China;Beijing Hospital of Traditional Chinese Medicine, Capital Medical University, 100010, Beijing, China;
关键词: MRI;    Glioblastoma;    Pseudoprogression;    Tumour progression;    Diffusion-weighted imaging;   
DOI  :  10.1186/s12880-023-01082-7
 received in 2022-12-10, accepted in 2023-08-19,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundTo investigate the diagnostic performance of parameters derived from monoexponential, biexponential, and stretched-exponential diffusion-weighted imaging models in differentiating tumour progression from pseudoprogression in glioblastoma patients.MethodsForty patients with pathologically confirmed glioblastoma exhibiting enhancing lesions after completion of chemoradiation therapy were enrolled in the study, which were then classified as tumour progression and pseudoprogression. All patients underwent conventional and multi-b diffusion-weighted MRI. The apparent diffusion coefficient (ADC) from a monoexponential model, the true diffusion coefficient (D), pseudodiffusion coefficient (D*) and perfusion fraction (f) from a biexponential model, and the distributed diffusion coefficient (DDC) and intravoxel heterogeneity index (α) from a stretched-exponential model were compared between tumour progression and pseudoprogression groups. Receiver operating characteristic curves (ROC) analysis was used to investigate the diagnostic performance of different DWI parameters. Interclass correlation coefficient (ICC) was used to evaluate the consistency of measurements.ResultsThe values of ADC, D, DDC, and α values were lower in tumour progression patients than that in pseudoprogression patients (p < 0.05). The values of D* and f were higher in tumour progression patients than that in pseudoprogression patients (p < 0.05). Diagnostic accuracy for differentiating tumour progression from pseudoprogression was highest for α(AUC = 0.94) than that for ADC (AUC = 0.91), D (AUC = 0.92), D* (AUC = 0.81), f (AUC = 0.75), and DDC (AUC = 0.88).ConclusionsMulti-b DWI is a promising method for differentiating tumour progression from pseudoprogression with high diagnostic accuracy. In addition, the α derived from stretched-exponential model is the most promising DWI parameter for the prediction of tumour progression in glioblastoma patients.

【 授权许可】

CC BY   
© BioMed Central Ltd., part of Springer Nature 2023

【 预 览 】
附件列表
Files Size Format View
RO202310116147830ZK.pdf 2461KB PDF download
12951_2023_2095_Article_IEq5.gif 1KB Image download
12951_2023_2095_Article_IEq8.gif 1KB Image download
MediaObjects/41408_2023_917_MOESM2_ESM.pdf 2729KB PDF download
Fig. 1 107KB Image download
13690_2023_1170_Article_IEq181.gif 1KB Image download
MediaObjects/12888_2023_5187_MOESM2_ESM.docx 17KB Other download
【 图 表 】

13690_2023_1170_Article_IEq181.gif

Fig. 1

12951_2023_2095_Article_IEq8.gif

12951_2023_2095_Article_IEq5.gif

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  文献评价指标  
  下载次数:8次 浏览次数:1次