期刊论文详细信息
BMC Anesthesiology
Supine transfer test-induced changes in cardiac index predict fluid responsiveness in patients without intra-abdominal hypertension
Research
Qionghua Lin1  Jing Liu1  Yijun Zheng1  Zhili Xia1  Lihua Shen1  Yaodong Zhang1  Zhiyong Zhao1  Danyan Gu1  Fangfang Li1  Biao Zhu1  Qian Xing1  Zhongwei Zhang1  Shan Zhang1  Pengmei Wang1 
[1] Department of Critical Care, Fudan University Shanghai Cancer Center, 200032, Shanghai, China;Department of Oncology, Shanghai Medical College, Fudan University, 200032, Shanghai, China;
关键词: Fluid responsiveness;    Supine transfer;    Cardiac index;    Intra-abdominal hypertension;   
DOI  :  10.1186/s12871-023-02280-0
 received in 2023-07-06, accepted in 2023-09-14,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundThe reversible maneuver that mimics the fluid challenge is a widely used test for evaluating volume responsiveness. However, passive leg raising (PLR) does have certain limitations. The aim of the study is to determine whether the supine transfer test could predict fluid responsiveness in adult patients with acute circulatory failure who do not have intra-abdominal hypertension, by measuring changes in cardiac index (CI).MethodsSingle-center, prospective clinical study in a 25-bed surgery intensive care unit at the Fudan University Shanghai Cancer Center. Thirty-four patients who presented with acute circulatory failure and were scheduled for fluid therapy. Every patient underwent supine transfer test and fluid challenge with 500 mL saline for 15–30 min. There were four sequential steps in the protocol: (1) baseline-1: a semi-recumbent position with the head of the bed raised to 45°; (2) supine transfer test: patients were transferred from the 45° semi-recumbent position to the strict supine position; (3) baseline-2: return to baseline-1 position; and (4) fluid challenge: administration of 500 mL saline for 15–30 min. Hemodynamic parameters were recorded at each step with arterial pulse contour analysis (ProAQT/Pulsioflex). A fluid responder was defined as an increase in CI ≥ 15% after fluid challenge. The receiver operating characteristic curve and gray zone were defined for CI.ResultsSeventeen patients were fluid challenge. The r value of the linear correlations was 0.73 between the supine transfer test- and fluid challenge-induced relative CI changes. The relative changes in CI induced by supine transfer in predicting fluid responsiveness had an area under the receiver operating characteristic curve of 0.88 (95% confidence interval 0.72–0.97) and predicted a fluid responder with 76.5% (95% confidence interval 50.1–93.2) sensitivity and 88.2% (95% confidence interval 63.6–98.5) specificity, at a best threshold of 5.5%. Nineteen (55%) patients were in the gray zone (CI ranging from -3 and 8 L/min/m2).ConclusionThe supine transfer test can potentially assist in detecting fluid responsiveness in patients with acute circulatory failure without intra-abdominal hypertension. Nevertheless, the small threshold and the 55% gray zone were noteworthy limitation.Trial registrationPredicting fluid responsiveness with supine transition test (ChiCTR2200058264). Registered 2022–04-04 and last refreshed on 2023–03-26, https://www.chictr.org.cn/showproj.html?proj=166175.

【 授权许可】

CC BY   
© BioMed Central Ltd., part of Springer Nature 2023

【 预 览 】
附件列表
Files Size Format View
RO202310114949443ZK.pdf 1373KB PDF download
Fig. 6 749KB Image download
Fig. 5 1835KB Image download
MediaObjects/12864_2023_9667_MOESM2_ESM.txt 296KB Other download
Fig. 5 193KB Image download
Fig. 5 767KB Image download
【 图 表 】

Fig. 5

Fig. 5

Fig. 5

Fig. 6

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  文献评价指标  
  下载次数:6次 浏览次数:0次