期刊论文详细信息
BMC Cardiovascular Disorders
Discrepancy between two invasive blood pressure measurements in patients receiving intra-aortic balloon pump therapy
Research
Lijuan Lu1  Shiyi Zhang1  Xiaoyan Zhao1  Yu Zhang1 
[1] Nursing Department, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1095, Jiefang Avenue, 430000, Wuhan, Hubei Province, China;
关键词: Cardiogenic shock;    Coronary care unit;    Invasive central aortic pressure;    Invasive peripheral arterial pressure;    Intra-aortic balloon pump;   
DOI  :  10.1186/s12872-023-03479-2
 received in 2023-04-18, accepted in 2023-08-29,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundHemodynamic monitoring is imperative for patients with cardiogenic shock undergoing Intra-aortic Balloon Pump (IABP) therapy. Blood pressure monitoring encompasses non-invasive, invasive peripheral arterial pressure (IPAP), and invasive central aortic pressure (ICAP) methods. However, marked disparities exist between IPAP and ICAP. This study examined the discrepancies between IPAP and ICAP and their clinical significance.MethodsA retrospective analysis was conducted on cardiogenic shock patients who underwent IABP therapy and were admitted to the Coronary Care Unit (CCU) of a tertiary hospital in China from March 2017 to November 2022. The Bland–Altman plot illustrated the discrepancy between IPAP and ICAP. A clinically significant difference between ICAP and IPAP measurements was defined as ≥ 10 mmHg, which could necessitate alterations in blood pressure management according to current guidelines that recommend maintaining a mean arterial pressure (MAP) ≥ 70 mmHg.ResultsIn total, 162 patients were included in the final analysis. In patients without vasopressors, the difference between ICAP and IPAP was 5.73 mmHg (95% limits of agreement [LOA], -16.98 to 28.44), whereas, in patients with vasopressors, it was 4.36 mmHg (95% LOA, -17.31 to 26.03). ICAP measurements exceeded IPAP in patients undergoing IABP therapy. However, the difference was not statistically significant between the two groups. Multivariate logistic regression revealed that higher serum lactate levels (Odds ratio [OR], 1.14; 95% confidence interval [CI], 1.03–1.27; p = 0.013) and age ≥ 60 years (OR, 13.20; 95% CI, 1.50–115.51; p = 0.020) were associated with an increased likelihood of a clinically significant MAP discrepancy. Conversely, a history of coronary heart disease was associated with a decreased likelihood (OR, 0.34; 95% CI, 0.13–0.90; p = 0.031).ConclusionsNotable discrepancies between ICAP and IPAP measurements exist in cardiogenic shock patients undergoing IABP therapy. ICAP exceeds IPAP, and factors such as age ≥ 60 years, elevated lactic acid levels, and absence of coronary heart disease contribute to this discrepancy. Enhanced vigilance is warranted for these patients, and the consideration of peripheral invasive monitoring in conjunction with IABP therapy is advised.

【 授权许可】

CC BY   
© BioMed Central Ltd., part of Springer Nature 2023

【 预 览 】
附件列表
Files Size Format View
RO202310113295972ZK.pdf 1520KB PDF download
42004_2023_990_Article_IEq11.gif 1KB Image download
Fig. 2 340KB Image download
12888_2023_5172_Article_IEq39.gif 1KB Image download
41408_2023_919_Article_IEq12.gif 1KB Image download
【 图 表 】

41408_2023_919_Article_IEq12.gif

12888_2023_5172_Article_IEq39.gif

Fig. 2

42004_2023_990_Article_IEq11.gif

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  文献评价指标  
  下载次数:5次 浏览次数:3次