BMC Cardiovascular Disorders | |
Vector flow mapping analysis of left ventricular vortex performance in type 2 diabetic patients with early chronic kidney disease | |
Research | |
Wei Wang1  Zhengqin Qi2  Lijuan Sun2  Kun Xue2  Damin Lyu2  Xiaoxue Chen3  Fang Qiu4  Degang Song5  | |
[1] Department of Cardiac Ultrasound, Second Hospital of Hebei Medical University, 215 Hepingxi Road, 050000, Shijiazhuang, Hebei, China;Department of Ultrasound, First Hospital of Qinhuangdao, Hebei Medical University, No.258, Wenhua Road, 066000, Qinhuangdao, Hebei, China;Department of Ultrasound, First Hospital of Qinhuangdao, Hebei Medical University, No.258, Wenhua Road, 066000, Qinhuangdao, Hebei, China;Hebei Key Laboratory of Vascular Homeostasis and Hebei Collaborative Innovation Center for Cardio- cerebrovascular Disease, No. 215, Hepingxi Road, 050000, Shijiazhuang, Hebei, China;Department of cardiology, First Hospital of Qinhuangdao, Hebei Medical University, No.258, Wenhua Road, 066000, Qinhuangdao, Hebei, China;Hebei Key Laboratory of Vascular Homeostasis and Hebei Collaborative Innovation Center for Cardio- cerebrovascular Disease, No. 215, Hepingxi Road, 050000, Shijiazhuang, Hebei, China;Department of neurology, First Hospital of Qinhuangdao, Hebei Medical University, No.258, Wenhua Road, 066000, Qinhuangdao, Hebei, China; | |
关键词: Left ventricular vortex; Vector flow mapping; Chronic kidney disease; Diastolic dysfunction; Glycemia; Early stages; | |
DOI : 10.1186/s12872-023-03474-7 | |
received in 2023-03-20, accepted in 2023-08-25, 发布年份 2023 | |
来源: Springer | |
【 摘 要 】
BackgroundDiabetes is the leading cause of chronic kidney disease (CKD) and contributes to an elevated incidence of diastolic dysfunction in the early stages of CKD. Intracardiac vortex is a novel hemodynamic index for perceiving cardiac status. Here, we visualized left ventricular (LV) vortex characteristics using vector flow mapping (VFM) in type 2 diabetic patients with early CKD.MethodsThis cross-sectional study included 67 controls and 89 type 2 diabetic patients with stages 2-3a CKD. All subjects underwent transthoracic echocardiographic examination. LV anterior vortex during early diastole (E-vortex), atrial contraction (A-vortex) and systole (S-vortex) were assessed using VFM in the apical long-axis view. Its relation to glycemia or LV filling echocardiographic parameters were further analyzed using correlation analysis.ResultsType 2 diabetic patients with early CKD had a small area (439.94 ± 132.37 mm2 vs. 381.66 ± 136.85 mm2, P = 0.008) and weak circulation (0.0226 ± 0.0079 m2/s vs. 0.0195 ± 0.0070 m2/s, P = 0.013) of E-vortex, but a large area (281.52 ± 137.27 mm2 vs. 514.83 ± 160.33 mm2, P ˂ 0.001) and intense circulation (0.0149 ± 0.0069 m2/s vs. 0.0250 ± 0.0067 m2/s, P < 0.001) of A-vortex compared to controls. CKD patients with poorly controlled hyperglycemia had stronger A-vortex (area: 479.06 ± 146.78 mm2 vs. 559.96 ± 159.27 mm2, P = 0.015; circulation: 0.0221 ± 0.0058 m2/s vs. 0.0275 ± 0.0064 m2/s, P < 0.001) and S-vortex (area: 524.21 ± 165.52 mm2 vs. 607.87 ± 185.33 mm2, P = 0.029; circulation: 0.0174 ± 0.0072 m2/s vs. 0.0213 ± 0.0074 m2/s, P = 0.015), and a longer relative duration of S-vortex (0.7436 ± 0.0772 vs. 0.7845 ± 0.0752, P = 0.013) than those who had well-controlled hyperglycemia. Glycemia, and E/A (a LV filling parameter) were respectively found to had close correlation to the features of A-vortex and S-vortex (all P < 0.05).ConclusionsAbnormal LV vortices were detected in type 2 diabetic patients with early CKD using VFM, especially in those who neglected hyperglycemic control. LV vortex might be a promising parameter to slow or halt the hyperglycemia-induced diastolic dysfunction in early CKD.
【 授权许可】
CC BY
© BioMed Central Ltd., part of Springer Nature 2023
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202310111185987ZK.pdf | 3739KB | download | |
Fig. 4 | 1250KB | Image | download |
12888_2023_5172_Article_IEq17.gif | 1KB | Image | download |
Fig. 1 | 160KB | Image | download |
Fig. 1 | 190KB | Image | download |
Fig. 2 | 1420KB | Image | download |
Fig. 3 | 1511KB | Image | download |
【 图 表 】
Fig. 3
Fig. 2
Fig. 1
Fig. 1
12888_2023_5172_Article_IEq17.gif
Fig. 4
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]