期刊论文详细信息
Frontiers in Toxicology
Inhalation of electronic cigarettes slightly affects lung function and inflammation in mice
Toxicology
Yuxing Dai1  Guangye Huang1  Jianwen Chen2  Peiqing Liu2  Kun Duan3  Xuemin Yang3  Xingtao Jiang3 
[1]Department of Pharmacology and Toxicology, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, Guangdong, China
[2]Department of Pharmacology and Toxicology, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, Guangdong, China
[3]National and Local Joint Engineering Laboratory of Druggability and New Drugs Evaluation, Guangdong Engineering Laboratory of Druggability and New Drug Evaluation, School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, China
[4]RELX Science Center, Shenzhen RELX Tech Co., Ltd., Shenzhen, China
关键词: electronic cigarette;    lung function;    cigarette;    inflammation;    toxicology;   
DOI  :  10.3389/ftox.2023.1232040
 received in 2023-05-31, accepted in 2023-07-14,  发布年份 2023
来源: Frontiers
PDF
【 摘 要 】
Electronic cigarettes have become increasingly popular, but the results of previous studies on electronic cigarette exposure in animals have been equivocal. This study aimed to evaluate the effects of electronic cigarette smoke (ECS) and cigarette smoke (CS) on lung function and pulmonary inflammation in mice to investigate whether electronic cigarettes are safer when compared to cigarettes. 32 specific pathogen-free BALB/c male mice were randomly grouped and exposed to fresh air (control), mint-flavored ECS (ECS1, 6 mg/kg), cheese-flavored ECS (ECS2, 6 mg/kg), and CS (6 mg/kg). After 3 weeks exposure to ECS or CS, we measured lung function (PIF and Penh) and blood oxygen saturation. The levels of TNF-α and IL-6 in the bronchoalveolar lavage fluid (BALF) and serum were measured using ELISA. HE staining was performed to observe the pathological changes in the lung tissues. The levels of IL-6 in BALF and serum, and TNF-α in BALF, were elevated similarly in the ECS and CS groups compared to the control group. Significant elevation was observed in serum TNF-α levels in the CS group. The total count of cells in BALF were increased after ECS1 exposure and CS exposure. PIF and oxygen saturation decreased, and Penh increased markedly in the CS group but not in the ECS groups. Compared with the ECS groups, mice in the CS group had widened lung tissue septa and increased inflammatory cell infiltration. However, we did not detect significant differences between mint-flavored and cheese-flavored e-cigarettes in our study. Overall, our findings suggested that both ECS and CS impair lung function and histopathology while promoting inflammation. In contrast, ECS has a less negative impact than CS.
【 授权许可】

Unknown   
Copyright © 2023 Dai, Duan, Huang, Yang, Jiang, Chen and Liu.

【 预 览 】
附件列表
Files Size Format View
RO202310109179081ZK.pdf 1796KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:1次