期刊论文详细信息
Frontiers in Physiology
Full-scale numerical simulation of hemodynamics based on left ventricular assist device
Physiology
Xinyi Gao1  Feng He1  Xiwen Zhang1  Zhike Xu1  Chenghan Chen1  Pengfei Hao2 
[1] Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China;Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China;Tsinghua University (School of Materials Science and Engineering)—AVIC Aerodynamics Research Institute Joint Research Center for Advanced Materials and Anti-Icing, Beijing, China;
关键词: heart failure;    aorta;    full-scale model;    hemodynamics;    LVAD;    CFD;   
DOI  :  10.3389/fphys.2023.1192610
 received in 2023-03-23, accepted in 2023-05-16,  发布年份 2023
来源: Frontiers
PDF
【 摘 要 】

Ventricular assist devices have been widely used and accepted to treat patients with end-stage heart failure. The role of VAD is to improve circulatory dysfunction or temporarily maintain the circulatory status of patients. In order to be closer to the medical practice, a multi-Domain model of the left ventricular coupled axial flow artificial heart was considered to study the effect of its hemodynamics on the aorta. Because whether LVAD itself was connected between the left ventricular apex and the ascending aorta by catheter in the loop was not very important for the analysis of simulation results, on the premise of ensuring the multi-Domain simulation, the simulation data of the import and export ends of LVAD were imported to simplify the model. In this paper, the hemodynamic parameters in the ascending aorta, such as blood flow velocity vector, wall shear stress distribution, vorticity current intensity, vorticity flow generation, etc., have been calculated. The numerical conclusion of this study showed the vorticity intensity under LVAD was significantly higher than that under patients’ conditions and the overall condition is similar to that of a healthy ventricular spin, which can improve heart failure patients’ condition while minimizing other pitfalls. In addition, high velocity blood flow during left ventricular assist surgery is mainly concentrated near the lining of the ascending aorta lumen. What’s more, the paper proposes to use Q criterion to determine the generation of vorticity flow. The Q criterion of LVAD is much higher than that of patients with heart failure, and the closer the LVAD is to the wall of the ascending aorta, the greater the Q criterion is. All these are beneficial to the effectiveness of LVAD in the treatment of heart failure patients and provide clinical suggestions for the LVAD implantation in clinical practice.

【 授权许可】

Unknown   
Copyright © 2023 Gao, Xu, Chen, Hao, He and Zhang.

【 预 览 】
附件列表
Files Size Format View
RO202310106920444ZK.pdf 2736KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次