期刊论文详细信息
Frontiers in Medicine
Methods for Measuring and Identifying Sounds in the Intensive Care Unit
Medicine
Martin grosse Holtforth1  Joerg C. Schefold2  Bjoern Zante2  Marie-Madlen Jeitziner3  Samuel E. J. Knobel4  Nicole Ruettgers4  Stephan M. Gerber4  Aileen C. Naef4  Tobias Nef5 
[1] Department of Clinical Psychology and Psychotherapy, University of Bern, Bern, Switzerland;Psychosomatic Medicine, Department of Neurology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland;Department of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland;Department of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland;Institute of Nursing Science (INS), Department of Public Health (DPH), Faculty of Medicine, University of Basel, Basel, Switzerland;Gerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland;Gerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland;Department of Neurology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland;
关键词: intensive care unit;    noise;    sound level meters;    hospital;    decibels;    sound pressure levels;    sound sources;   
DOI  :  10.3389/fmed.2022.836203
 received in 2021-12-15, accepted in 2022-04-29,  发布年份 2022
来源: Frontiers
PDF
【 摘 要 】

BackgroundDespite many studies in the field examining excessive noise in the intensive care unit, this issue remains an ongoing problem. A limiting factor in the progress of the field is the inability to draw conclusions across studies due to the different and poorly reported approaches used. Therefore, the first goal is to present a method for the general measurement of sound pressure levels and sound sources, with precise details and reasoning, such that future studies can use these procedures as a guideline. The two procedures used in the general method will outline how to record sound pressure levels and sound sources, using sound level meters and observers, respectively. The second goal is to present the data collected using the applied method to show the feasibility of the general method and provide results for future reference.MethodsThe general method proposes the use of two different procedures for measuring sound pressure levels and sound sources in the intensive care unit. The applied method uses the general method to collect data recorded over 24-h, examining two beds in a four-bed room, via four sound level meters and four observers each working one at a time.ResultsThe interrater reliability of the different categories was found to have an estimate of >0.75 representing good and excellent estimates, for 19 and 16 of the 24 categories, for the two beds examined. The equivalent sound pressure levels (LAeq) for the day, evening, and night shift, as an average of the sound level meters in the patient room, were 54.12, 53.37, and 49.05 dBA. In the 24-h measurement period, talking and human generated sounds occurred for a total of 495 (39.29% of the time) and 470 min (37.30% of the time), at the two beds of interest, respectively.ConclusionA general method was described detailing two independent procedures for measuring sound pressure levels and sound sources in the ICU. In a continuous data recording over 24 h, the feasibility of the proposed general method was confirmed. Moreover, good and excellent interrater reliability was achieved in most categories, making them suitable for future studies.

【 授权许可】

Unknown   
Copyright © 2022 Naef, Knobel, Ruettgers, Jeitziner, Holtforth, Zante, Schefold, Nef and Gerber.

【 预 览 】
附件列表
Files Size Format View
RO202310103038982ZK.pdf 1049KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:1次