期刊论文详细信息
Frontiers in Physiology
Determination of optimal load in the Wingate Anaerobic Test is not depend on number of sprints included in mathematical models
Physiology
Kamil Michalik1  Marcin Smolarek1  Marek Zatoń2  Bartosz Ochmann2 
[1] Department of Human Motor Skills, Faculty of Physical Education and Sport, Wroclaw University of Health and Sport Sciences, Wrocław, Poland;Department of Physiology and Biochemistry, Faculty of Physical Education and Sport, Wroclaw University of Health and Sport Sciences, Wrocław, Poland;
关键词: wingate test;    peak power output;    force-velocity;    anaerobic performance;    braking force;    all-out exercise;   
DOI  :  10.3389/fphys.2023.1146076
 received in 2023-01-16, accepted in 2023-05-16,  发布年份 2023
来源: Frontiers
PDF
【 摘 要 】

Determining the optimal load (OPTLOAD) in measuring mechanical peak power output (PPO) is important in assessment of anaerobic fitness. The main goals of this study were: 1) to examine estimated optimal load and PPO based on a force-velocity test and 2) to compare the PPO from the previous method with the Wingate Anaerobic Test (WAnT). The study involved 15 academic male athletes, aged 22.4 ± 2.3 (years), height 178.9 ± 6.8 (cm), and body weight 77.9 ± 12.2 (kg). They performed the 30-s WAnT (7.5% of body weight) during the first visit to the laboratory. Second to fourth session included a force-velocity test (FVT) involving three, 10-s all-out sprints. A randomized load ranging from 3 to 11 kg was used in each session for FVT. The OPTLOAD and PPO were computed using quadratic relationships based on power-velocity (P-v) and power-percent of body weight (P-%BM) and including three, four, five and nine sprints from FVT. The results showed non-difference in OPTLOAD [13.8 ± 3.2 (%BM); 14.1 ± 3.5 (%BM); 13.5 ± 2.8 (%BM); 13.4 ± 2.6 (%BM)] executed at three, four, five, and nine sprints (F3,56 = 0.174, p = 0.91, η2 = 0.01). The two-way ANOVA revealed that PPO were similar between tested models (P-%BM vs. P-v) independently from the numbers of sprints (F3,112 = 0.08, p = 0.99, η2 = 0.000). Moreover, the PPO measured in the WAnT (870.6 ± 179.1 W) was significantly lower compared with in P-v model (1,102.9 ± 242.5–1,134.2 ± 285.4 W) (F4,70 = 3.044, p = 0.02, η2 = 0.148). In addition, the PPO derived from P-%BM model (1,105.2 ± 245.5–1,138.7 ± 285.3 W) was significantly higher compared with the WAnT (F4,70 = 2.976, p = 0.02, η2 = 0.145). The findings suggest the potential utility of FVT for assessment of anaerobic capacity.

【 授权许可】

Unknown   
Copyright © 2023 Michalik, Smolarek, Ochmann and Zatoń.

【 预 览 】
附件列表
Files Size Format View
RO202310101754003ZK.pdf 1042KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:2次