期刊论文详细信息
Frontiers in Immunology
Interkit Reproducibility of the Indirect Immunofluorescence Assay on HEp-2 Cells Depends on the Immunofluorescence Reactivity Intensity and Pattern
Immunology
Alessandra Dellavance1  Danielle Cristiane Baldo1  Luís Eduardo Coelho Andrade2  Mônica Jesus Silva2  Monica Simon Prado2  Silvia Helena Rodrigues2  Marcelle Grecco2  Renan Agustinelli2 
[1] Research and Development Division, Fleury Medicine and Health Laboratories, São Paulo, Brazil;Rheumatology Division, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil;
关键词: autoantibody;    antinuclear antibodies;    immunofluorescence;    HEp-2 cells;    autoimmune diseases;   
DOI  :  10.3389/fimmu.2021.798322
 received in 2021-10-20, accepted in 2021-12-20,  发布年份 2022
来源: Frontiers
PDF
【 摘 要 】

IntroductionThe indirect immunofluorescence assay on HEp-2 cells (HEp-2/IFA) is used worldwide for screening for autoantibodies to cellular antigens. Cell culture and fixation methods influence the cell distribution of autoantigens and the preservation of epitopes. Therefore, discrepancy of results obtained using different HEp-2/IFA kits (interkit nonreproducibility) is a common phenomenon in the clinical laboratory routine.ObjectiveThis study evaluated the interkit nonreproducibility of HEp-2/IFA results using samples from patients with systemic autoimmune disease (SAD), nonautoimmune diseases (NAD), and healthy blood donors (HBD).MethodsSerum from 275 SAD patients, 293 NAD patients, and 300 HBD were processed at 1:80 dilution using four HEp-2 kits according to the manufacturers’ instructions. Interkit reproducibility was determined for positive/negative results and patterns. The agreement of positive/negative results among kits for each sample was determined as the reactivity agreement score (RAS). The pattern reproducibility score (PRS) in each sample was calculated as a function of the number of kits showing equivalent patterns. Qualitative variables and ordinal variables were analyzed by the Chi-square and Mann-Whitney U tests, respectively.ResultsA total of 402 samples were nonreactive in all kits and were considered devoid of autoantibodies. Further analysis included the 466 reactive samples (238 SAD, 119 NAD, 109 HBD). Reactivity to the nucleus had the highest interkit reproducibility (RAS = 83.6), followed by the metaphase plate (RAS = 78.9), cytoplasm (RAS = 77.4), and nucleolus (RAS = 72.4). Interkit reproducibility was higher in SAD (RAS = 78.0) than in NAD (RAS = 70.6) and HBD (RAS = 71.3) groups. Samples with strong reactivity (++++/4 and +++/4) had higher interkit reproducibility than those with weak reactivity (+/4). In the SAD group, RAS for nuclear reactivity was 87.5% for strongly reactive samples as opposed to 4.4% for weakly reactive samples, and the same was observed for NAD and HBD samples. The most robust patterns were the centromere AC-3 (PRS = 78.4), multiple nuclear dots AC-6 (PRS = 73.6), nuclear coarse speckled AC-5 (PRS = 71.3), nuclear homogeneous AC-1 (PRS = 67.9), and the reticular cytoplasmic AC-21 (PRS = 68.6).ConclusionInterkit nonreproducibility in HEp-2/IFA is prevalent and occurs with the highest frequency with weakly reactive samples. International initiatives with the engagement of in vitro diagnostic industry are encouraged to promote the harmonization of the properties and performance of HEp-2/IFA commercial kits.

【 授权许可】

Unknown   
Copyright © 2022 Silva, Dellavance, Baldo, Rodrigues, Grecco, Prado, Agustinelli and Andrade

【 预 览 】
附件列表
Files Size Format View
RO202310101141968ZK.pdf 3447KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:1次