期刊论文详细信息
International Journal of Concrete Structures and Materials
Effect of Contents, Tensile Strengths and Aspect Ratios of Hooked-End Steel Fibers (SFs) on Compressive and Flexural Performance of Normal Strength Concrete
Research
Seok-Joon Jang1  Dong-Hui Kim2  Woo-Jin Jeong2  Qi Wang2  Ai-Hua Jin2  Hyun-Do Yun2  Sun-Woo Kim3  Wan-Shin Park3 
[1] Building Management Support Center, Korea Authority of Land & Infrastructure, 52856, Jinju, Republic of Korea;Department of Architectural Engineering, Chungnam National University, 34134, Daejeon, Republic of Korea;Department of Construction Engineering Education, Chungnam National University, 34134, Daejeon, Republic of Korea;
关键词: Steel fiber reinforced concrete (SFRC);    Compressive behavior;    Flexural behavior;    Toughness;    Residual flexural strength;   
DOI  :  10.1186/s40069-023-00611-6
 received in 2022-12-07, accepted in 2023-05-03,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

This study is a part of the study to simplify the reinforcing details of reinforced concrete (RC) structural members by substituting the conventional reinforcement with hooked-end steel fibers (SFs). This paper investigates the effects of SF strength, dosage and aspect (l/d) ratio on the compressive and flexural behaviors of normal strength concrete with specified compressive strength of 30 MPa. In this study, hooked-end SFs of high strength (2000–2400 MPa) and normal strength (1100–1200 MPa) were used with three l/d ratios of 64, 67 and 80. Hooked-end SFs were incorporated with three dosages of 20 kg/m3 (0.25 vol.%), 40 kg/m3 (0.50 vol.%) and 60 kg/m3 (0.75 vol.%). Eighteen steel fiber reinforced concrete (SFRC) mixes were mixed. To evaluate the compressive and flexural performance of each SFRC mixture, three SFRC cylindrical and prismatic specimens for each mixture were manufactured and tested, respectively. The test results that the inclusion of hooked-end SFs had little effect on the compressive strength, while it improved the toughness of concrete. Hooked-end SFs were also found to be effective in enhancing the flexural performance of concrete. The dosage and properties (strength and l/d ratio) of SFs significantly affect the residual flexural tensile strength (fR1 and fR3) at serviceability (SLS) and ultimate limit state (ULS) defined in fib Model Code 2010 (MC2010).

【 授权许可】

CC BY   
© The Author(s) 2023

【 预 览 】
附件列表
Files Size Format View
RO202309155339464ZK.pdf 4580KB PDF download
40517_2023_261_Article_IEq6.gif 1KB Image download
MediaObjects/41408_2023_892_MOESM3_ESM.tif 3496KB Other download
Fig. 4 2819KB Image download
Fig. 2 478KB Image download
MediaObjects/42358_2023_307_MOESM1_ESM.docx 11KB Other download
Fig. 2 40KB Image download
MediaObjects/12974_2023_2855_MOESM6_ESM.tif 36752KB Other download
13690_2023_1147_Article_IEq18.gif 1KB Image download
Fig. 4 544KB Image download
Fig. 1 2029KB Image download
Fig. 5 217KB Image download
Fig. 4 695KB Image download
Fig. 2 516KB Image download
Fig. 3 315KB Image download
Fig. 8 513KB Image download
Fig. 5 745KB Image download
Fig. 3 933KB Image download
Fig. 2 255KB Image download
【 图 表 】

Fig. 2

Fig. 3

Fig. 5

Fig. 8

Fig. 3

Fig. 2

Fig. 4

Fig. 5

Fig. 1

Fig. 4

13690_2023_1147_Article_IEq18.gif

Fig. 2

Fig. 2

Fig. 4

40517_2023_261_Article_IEq6.gif

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  • [44]
  • [45]
  文献评价指标  
  下载次数:8次 浏览次数:3次