期刊论文详细信息
BMC Chemistry
LC–MS/MS separation and quantitation of ribavirin in chicken and comparison of different mass spectrometric platforms
Research
Daokun Xu1  Jun Yang1  Xinmei Liu2  Wenyan Hu3  Haolun Huang4 
[1]Nanjing Institute for Food and Drug Control, 211198, Nanjing, Jiangsu Province, People’s Republic of China
[2]Nanjing Institute for Food and Drug Control, 211198, Nanjing, Jiangsu Province, People’s Republic of China
[3]Collaborative Laboratory for Food Safety, Nanjing Institute for Food and Drug Control and SCIEX (China), 211198, Nanjing, Jiangsu Province, People’s Republic of China
[4]Nanjing Institute for Food and Drug Control, 211198, Nanjing, Jiangsu Province, People’s Republic of China
[5]Demonstration Collaborative Laboratory of Analysis and Detection Technology for Food and Drug Safety, Nanjing Institute for Food and Drug Control and Agilent Technologies (China), 211198, Nanjing, Jiangsu Province, People’s Republic of China
[6]Nanjing Institute for Food and Drug Control, 211198, Nanjing, Jiangsu Province, People’s Republic of China
[7]State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, 214122, Wuxi, Jiangsu Province, People’s Republic of China
关键词: LC–MS/MS;    Anti–viral drug;    Ribavirin;    Separation;    Chicken;   
DOI  :  10.1186/s13065-023-01010-4
 received in 2023-04-12, accepted in 2023-08-01,  发布年份 2023
来源: Springer
PDF
【 摘 要 】
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for the analysis of ribavirin in chicken. Samples was extracted with 0.1% formic acid and purified by Hypercarb cartridge prior to LC–MS/MS analysis. The eluates were evaporated to dryness, reconstituted in 1 mL 5mM ammonium acetate containing 5% acetonitrile (v/v) and 0.1% (v/v) formic acid. Chromatographic separation was performed on a Hypercarb analytical column under a gradient elution program with acetonitrile and 0.1% (v/v) formic acid in 5 mM ammonium acetate at a flow rate of 0.6 ml/min. The intraday and interday accuracy ranged from − 7.83 − 1.39%, and − 6.38 − 2.25%, with precisions between 1.34 − 3.88%% and 1.10 − 4.67%. The limits of detection (LODs) and limits of quantitation (LOQs) of ribavirin was 0.1 ng/mL and 0.5 ng/mL, respectively. The method was validated for linearity, accuracy, precision, matrix effect and stability. Application of the method confirmed 3 ribavirin positive samples out of 50 commercial chicken samples, with concentrations of ribavirin ranging from 0.9 μg/kg to 5.8 μg/kg a, respectively. Additionally, both AB Sciex 5500 and Agilent 6945B were proven to be suitable in ribavirin separation and quantification. The described method is suitable for the determination of ribavirin in chicken in analytical practice to monitor illegal addition of this kind of anti–viral drug.
【 授权许可】

CC BY   
© Springer Nature Switzerland AG 2023

【 预 览 】
附件列表
Files Size Format View
RO202309152710739ZK.pdf 1195KB PDF download
Fig. 3 35KB Image download
13570_2023_282_Article_IEq9.gif 1KB Image download
Fig. 4 253KB Image download
【 图 表 】

Fig. 4

13570_2023_282_Article_IEq9.gif

Fig. 3

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  文献评价指标  
  下载次数:0次 浏览次数:0次