期刊论文详细信息
BMC Musculoskeletal Disorders
Influence of ultrasound machine settings on quantitative measures derived from spatial frequency analysis of muscle tissue
Research
Greg R. Bashford1  Scott K. Crawford2  Stephanie A. Kliethermes3  Bryan C. Heiderscheit4 
[1] Department of Biological Systems Engineering, University of Nebraska, Lincoln, NE, USA;Department of Kinesiology, University of Wisconsin-Madison, 1300 University Ave, 53706, Madison, WI, USA;Department of Orthopedics & Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA;Department of Orthopedics & Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA;Badger Athletic Performance Program, University of Wisconsin-Madison, Madison, WI, USA;Department of Orthopedics & Rehabilitation, University of Wisconsin-Madison, Madison, WI, USA;Badger Athletic Performance Program, University of Wisconsin-Madison, Madison, WI, USA;Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA;
关键词: Ultrasonography;    Hamstring muscles;    Spatial frequency;    Musculoskeletal;    Imaging;   
DOI  :  10.1186/s12891-023-06790-3
 received in 2023-03-02, accepted in 2023-08-09,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundUltrasound is a powerful tool for diagnostic purposes and provides insight into both normal and pathologic tissue structure. Spatial frequency analysis (SFA) methods characterize musculoskeletal tissue organization from ultrasound images. Both sonographers in clinical imaging and researchers may alter a minimized range of ultrasound settings to optimize image quality, and it is important to know how these small adjustments of these settings affect SFA parameters. The purpose of this study was to investigate the effects of making small adjustments in a typical default ultrasound machine setting on extracted spatial frequency parameters (peak spatial frequency radius (PSFR), Mmax, Mmax%, and Sum) in the biceps femoris muscle.MethodsLongitudinal B-mode images were collected from the biceps femoris muscle in 36 participants. The window depth, foci locations, and gain were systematically adjusted consistent with clinical imaging procedures for a total of 27 images per participant. Images were analyzed by identifying a region of interest (ROI) in the middle portion of the muscle belly in a template image and using a normalized two-dimensional cross-correlation technique between the template image and subsequent images. The ROI was analyzed in the frequency domain using conventional SFA methods. Separate linear mixed effects models were run for each extracted parameter.ResultsPSFR was affected by modifications in focus location only (p < 0.001) with differences noted between all locations. Mmax% was influenced by the interaction of gain and focus location (p < 0.001) but was also independently affected by increasing window depth (p < 0.001). Both Mmax and Sum parameters were sensitive to small changes in machine settings with the interaction of focus location and window depth (p < 0.001 for both parameters) as well as window depth and gain (p < 0.001 for both) influencing the extracted values.ConclusionsFrequently adjusted imaging settings influence some SFA statistics. PSFR and Mmax% appear to be most robust to small changes in image settings, making them best suited for comparison across individuals and between studies, which is appealing for the clinical utility of the SFA method.

【 授权许可】

CC BY   
© BioMed Central Ltd., part of Springer Nature 2023

【 预 览 】
附件列表
Files Size Format View
RO202309150720477ZK.pdf 4582KB PDF download
Fig. 3 1592KB Image download
Fig. 2 223KB Image download
Fig. 3 45KB Image download
Fig. 3 477KB Image download
41512_2023_153_Article_IEq116.gif 1KB Image download
Fig. 2 437KB Image download
Fig. 9 5258KB Image download
MediaObjects/41021_2023_275_MOESM3_ESM.pdf 408KB PDF download
40798_2023_622_Article_IEq7.gif 1KB Image download
Fig. 5 1411KB Image download
Fig. 5 192KB Image download
Fig. 2 66KB Image download
Fig. 5 477KB Image download
【 图 表 】

Fig. 5

Fig. 2

Fig. 5

Fig. 5

40798_2023_622_Article_IEq7.gif

Fig. 9

Fig. 2

41512_2023_153_Article_IEq116.gif

Fig. 3

Fig. 3

Fig. 2

Fig. 3

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  文献评价指标  
  下载次数:10次 浏览次数:0次