BMC Ophthalmology | |
Evaluation and comparison of ocular biometric parameters obtained with Tomey OA-2000 in silicone oil-filled aphakic eyes | |
Research | |
Yongdong Lin1  Zifeng Zhao1  Hongxi Wang1  Guihua Zhang1  Yongqun Xiong1  | |
[1] Joint Shantou International Eye Center of Shantou University, The Chinese University of Hong Kong, Dong xia Road, Shantou, Guangdong Province, People’s Republic of China; | |
关键词: Ocular biometry; Silicone oil-filled eyes; Retinal disease; Swept-source optical coherence tomography; | |
DOI : 10.1186/s12886-023-02962-w | |
received in 2022-09-15, accepted in 2023-05-05, 发布年份 2023 | |
来源: Springer | |
【 摘 要 】
PurposeTo evaluate a new non-contact instrument (OA-2000) measuring the ocular biometry parameters of silicone oil (SO)-filled aphakic eyes, as compared with IOLMaster 700.MethodsForty SO-filled aphakic eyes of 40 patients were enrolled in this cross-sectional clinical trial. The axial length (AL), central corneal thickness (CCT), keratometry ((flattest keratometry) Kf and (steep keratometry, 90° apart from Kf) Ks), and axis of the Kf (Ax1) were measured with OA-2000 and IOLMaster 700. The coefficient of variation (CoV) was calculated to assess the repeatability. The correlation was evaluated by the Pearson coefficient. Bland-Altman analysis and paired t test were used to analyze the agreements and differences of parameters measured by the two devices, respectively.ResultsThe mean AL obtained with the OA-2000 was 23.57 ± 0.93 mm (range: 21.50 to 25.68 mm), and that obtained with the IOLMaster 700 was 23.69 ± 0.94 mm (range: 21.85 to 25.86 mm), resulting in a mean offset of 0.124 ± 0.125 mm (p < 0.001). The mean offset of CCT measured by OA-2000 and IOLMaster 700 was 14.6 ± 7.5 μm (p < 0.001). However, the Kf, Ks and Ax1 values from the two devices were comparable (p > 0.05). All the measured parameters of the two devices showed strong linear correlations (all r ≥ 0.966). The Bland-Altman analysis showed a narrow 95% limits of agreement (LoA) of Kf, Ks and AL, but 95%LoA of CCT and Ax1 was wide, which were − 29.3 ~ 0.1 μm and-25.9 ~ 30.7°respectively. The CoVs of the biometric parameters obtained with OA-2000 were lower than 1%.ConclusionIn SO-filled aphakic eyes, the ocular parameters (including AL, Kf, Ks, Ax1, and CCT) measured by the OA-2000 and IOLMaster 700 had a good correlation. Two devices had an excellent agreement on ocular biometric measurements of Kf, Ks and AL. The OA-2000 provided excellent repeatability of ocular parameters in SO-filled aphakic eyes.
【 授权许可】
CC BY
© The Author(s) 2023
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO202308156686588ZK.pdf | 1668KB | download | |
MediaObjects/12888_2023_4867_MOESM8_ESM.docx | 17KB | Other | download |
41116_2023_36_Article_IEq413.gif | 1KB | Image | download |
Fig. 1 | 835KB | Image | download |
41116_2023_36_Article_IEq417.gif | 1KB | Image | download |
41116_2023_36_Article_IEq419.gif | 1KB | Image | download |
【 图 表 】
41116_2023_36_Article_IEq419.gif
41116_2023_36_Article_IEq417.gif
Fig. 1
41116_2023_36_Article_IEq413.gif
【 参考文献 】
- [1]
- [2]
- [3]
- [4]
- [5]
- [6]
- [7]
- [8]
- [9]
- [10]
- [11]
- [12]
- [13]
- [14]
- [15]
- [16]
- [17]
- [18]
- [19]
- [20]
- [21]
- [22]
- [23]
- [24]
- [25]
- [26]
- [27]
- [28]
- [29]
- [30]
- [31]
- [32]
- [33]
- [34]
- [35]
- [36]
- [37]
- [38]
- [39]