期刊论文详细信息
BMC Ophthalmology
Evaluation of different treatment modalities on the efficacy of hydroxypropyl Guar (HP-Guar) formulation on tear film stability (TFS) in subjects exposed to adverse environmental conditions
Research
Suhail Razak1  Tayyaba Afsar1  Ali Alsaqr2  Ali Abusharha2  Raied Fagehi2  Ian E. Pearce3 
[1] Department of Community Health Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia;Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia;Vision Sciences, Glasgow Caledonian University, Glasgow, Scotland, UK;
关键词: Dry eye;    Tear film stability;    Tear evaporation rate;    Controlled environment chamber;    Desiccating environment;    Hydroxypropyl guar;    Treatment modalities;   
DOI  :  10.1186/s12886-023-02977-3
 received in 2023-02-02, accepted in 2023-05-13,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

The study aimed to assess the efficacy of hydroxypropyl guar (HP) formulation (Systane) to protect tear film parameters under desiccating environment using protection and relief treatment modalities. The subjects were exposed to adverse environmental conditions using a Controlled Environment Chamber (CEC) where the relative humidity (RH) was 5% and the ambient temperature was 21 °C and screened for Tear break-up time (TBUT), Tear film evaporation rate (TFER) and lipid layer thickness (LLT) using the HIRCAL grid, Servomed EP3 Evaporimeter and Keeler’s TearScope-Plus respectively. Significant improvement in LLT was noticed in the protection modality. The mean tear film evaporation rate doubled after exposure to the humidity of 5% to a value of 105.37 g/m2/h (0.29 µl/min). All subjects displayed a significant reduction in non-invasive tear break-up time (NITBUT) with a mean NITBUT of 7.7 s after exposure to a desiccating environment for 15 min. A significant increase in NITBUT after the instillation of the drops was recorded in both methods. The results obtained from this study showed that a solution containing HP-Guar significantly improves tear film parameters under a desiccating environment. Apart from the tear evaporation rate, all tear parameters showed improvement after the use of HP-Guar eye drops. It is evident that tear film parameters respond differently to the management modalities and using CEC has the potential to provide researchers with a readily available method to evaluate the efficiency of tear supplementation.

【 授权许可】

CC BY   
© The Author(s) 2023

【 预 览 】
附件列表
Files Size Format View
RO202308155597732ZK.pdf 1551KB PDF download
MediaObjects/41408_2023_794_MOESM1_ESM.pdf 394KB PDF download
Fig. 7 207KB Image download
41116_2023_36_Article_IEq232.gif 1KB Image download
41116_2023_36_Article_IEq235.gif 1KB Image download
41116_2023_36_Article_IEq270.gif 1KB Image download
41116_2023_36_Article_IEq301.gif 1KB Image download
【 图 表 】

41116_2023_36_Article_IEq301.gif

41116_2023_36_Article_IEq270.gif

41116_2023_36_Article_IEq235.gif

41116_2023_36_Article_IEq232.gif

Fig. 7

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  • [44]
  • [45]
  • [46]
  文献评价指标  
  下载次数:4次 浏览次数:0次