期刊论文详细信息
BMC Oral Health
Surface hardness and flexural strength of dual-cured bulk-fill restorative materials after solvent storage
Research
Bashayer Alzahrani1  Wedad Awliya1  Abdulrahman Alshabib1 
[1] Department of Restorative Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia;
关键词: Dual-cured;    Bulk-fill resin;    Surface hardness;    Flexural strength;    Solvent storage;   
DOI  :  10.1186/s12903-023-03047-2
 received in 2023-03-25, accepted in 2023-05-15,  发布年份 2023
来源: Springer
PDF
【 摘 要 】

BackgroundThis study aimed to evaluate the surface hardness (VHN) and biaxial flexural strength (BFS) of dual-cured bulk-fill restorative materials after solvent storage.MethodsTwo dual-cured bulk-fill composites (Surefil One® and Activa™ Bioactive), a light-cured bulk-fill composite (Filtek One Bulk-Fill) and a resin-modified glass ionomer (Fuji II LC) were investigated. Surefil One and Activa were used in the dual-cure mode, all materials were handled according to manufacturer’s instructions. For VHN determination, 12 specimens were prepared from each material and measured after 1 h (baseline), 1 d, 7 d and 30 d of storage in either water or 75% ethanol–water. For BFS test, 120 specimens were prepared (n = 30/material) and stored in water for either 1, 7 or 30 d before testing. Repeated measures MANOVA, two-way and one-way ANOVA followed by the Tukey post hoc test (p ≤ 0.05) were used to analyze the data.ResultsFiltek One had the highest VHN, while Activa had the lowest. All materials exhibited a significant increase in VHN after 1d of storage in water, except for Surefil One. After 30 d of storage, VHN increased significantly in water except for Activa, while ethanol storage caused a significant time-dependent reduction in all tested materials (p ≤ 0.05). Filtek One showed the highest BFS values (p ≤ 0.05). All the materials, except for Fuji II LC, exhibited no significant differences between 1 and 30 d BFS measurements (p > 0.05).ConclusionsDual-cured materials had significantly lower VHN and BFS compared to the light-cured bulk-fill material. The low results of Activa VHN and Surefil One BFS, indicate that these materials should not be recommended in posterior stress-bearing areas.

【 授权许可】

CC BY   
© The Author(s) 2023

【 预 览 】
附件列表
Files Size Format View
RO202308153161726ZK.pdf 3064KB PDF download
MediaObjects/12888_2023_4761_MOESM1_ESM.docx 55KB Other download
Fig. 3 965KB Image download
41116_2023_36_Article_IEq731.gif 1KB Image download
Fig. 1 262KB Image download
【 图 表 】

Fig. 1

41116_2023_36_Article_IEq731.gif

Fig. 3

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  • [38]
  • [39]
  • [40]
  • [41]
  • [42]
  • [43]
  • [44]
  • [45]
  • [46]
  • [47]
  • [48]
  • [49]
  • [50]
  • [51]
  • [52]
  • [53]
  • [54]
  文献评价指标  
  下载次数:12次 浏览次数:4次